IL8 Series
IL8-1 Element Performance
Efficiency Capacity
PSID BAR
100
Beta Rating Efficiency %
10000
6
2QQ
2 2Q 5Q5Q
80
2Q
2Q
99.9 5
5Q
5Q
1000
10Q0Q 10Q
1 10Q
10Q
20Q
20Q
60 4
200
99.5
100 99.0
20Q0Q
2 20Q 3
40
2
20 95.0
20
1
2
50.0
0 0
0 20 40 60 80 100 120 140 160
0 4 8 12 16 20
Capacity grams
Micron Size (c)
Results typical from Multi-pass tests run per test standard ISO 16889 @ 40 gpm to 60 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
LPM LPM
0 100 200 300 400 500 0 100 200 300 400 500
25 5
150SUS
Empty Housing
1.5 0.30
20 4
SAE-24 0.25
15 3
PSID 02Q 1.0 BAR PSID SAE-32 0.20 BAR
10 2 0.15
05Q SAE-2” Flange Face
0.5 0.10
10Q SAE-2½” Flange Face
5 1
20Q 0.05
0.0
0 0
0.0
0 30 60 90 120 150 0 30 60 90 120 150
GPM GPM