Page 97 - Parker - Hydraulic and Lube Filtration Products
P. 97
IL8 Series
IL8-2 Element Performance
Efficiency Capacity
PSID BAR
Beta Rating Efficiency %
60
10000 4
2QQ
2 2Q 5Q5Q
50
2Q
2Q
5Q
5Q
10Q
10Q 3
99.9
1000
10Q0Q 20Q
1 10Q
20Q
40
200 99.5
30 2
100 99.0
20Q0Q
2 20Q
20
20 95.0
1
10
2
50.0
0 0
0 60 120 180 240 300 360 420
0 4 8 12 16 20
Capacity grams
Micron Size (c)
Results typical from Multi-pass tests run per test standard ISO 16889 @ 50 gpm to 60 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
LPM LPM
0 200 400 600 800 1000 0 200 400 600 800 1000
25 10
150SUS 150SUS
Empty Housing
1.5 0.6
20 8
SAE-32 0.5
15 6 SAE-2” Flange Face
PSID 02Q 1.0 BAR PSID SAE-24 0.4 BAR
10 4 SAE-2½” Flange Face 0.3
05Q 0.5 0.2
10Q
5 2
20Q 0.1
0.0
0 0
0.0
0 50 100 150 200 250 300
0 50 100 150 200 250 300
GPM GPM
92