Page 19 - Scanreco - Instruction Manual: G5 rocket flex/pocket system
P. 19
19/33
6.5 Technical data Receiver G5 5R & R10
Attribute Information Attribute Information
Power Supply 9-36 VDC Power Supply 9-36 VDC
IP-Class IP67 IP-Class IP65
Connector Interface 2 x 12 pin Deutsch connectors Connector Interface Spring terminal block (tool free assembly)
Programming interface RS232 Programming interface RS232
Overload Protection Yes, maximum 36 VDC Overload Protection Yes, maximum 36 VDC
Current consumption <30 mA (idle), 60 mA + External loads in operation Current consumption <30 mA (idle)
Digital Inputs 14 (can also be used as digital outputs) Do not exceed supply voltage. 60 mA + External loads in operation
Digital Outputs 19 MOSFET driven outputs, Short circuit proof, overload protected. Digital Outputs 5 or 10 digital outputs. Each output (relay) needs to be supplied with power
through the terminal connector. External fuse is recomended.
E-Stop Output Active when system is operational, short circuit proof, overload pro- Not short circuit proof, not overload protected, max. 5 Ampere load/output.
tected. Each output is electrically isolated.
Max output load 3A/output, 5A/bank, 10A/system
Cable Glands 2, dimension 8-13mm (0,31-0,51 in.)
Bank 1 2 3 4 5 6 7 8 9 10
Housing screw torque 0.8 Nm
Output 1,Estop 2,3 4,5 6,16 7,9 8,10 11,12 13,17 18,19 14,15
Ambient Temperature -25°C to +70°C ~ -15°F to +160°F
Housing screw torque 0.8 Nm
Ambient Temperature -25°C to +70°C ~ -15°F to +160°F Weight 0,35 Kg ~ 0.77 lbs
Weight 0,5 Kg ~ 1.10 lbs
B1 = REL6, common A1 = GND
B2 = REL6, normally closed A2 = Power Supply +
B3 = REL6, normally open A3 = REL1, common
B4 = REL7, common A4 = REL1, normally closed
B5 = REL7, normally closed A5 = REL1, normally open
B6 = Rel7, normally open A6 = REL2, common
B7 = REL8, common A7 = REL2, normally closed
B8 = REL8, normally closed A8 = REL2, normally open
B9 = REL8, normally open A9 = REL3, common
B10 = REL9, common 1 15 A10 = REL3, normally closed
B11 = REL9, normally closed A11 = REL3, normally open
B12 = REL9, normally open 1 17 A12 = REL4, common
B13 = REL10, common A13 = REL4, normally closed
B14 = REL10, normally closed A14 = REL4, normally open
B15 = REL10, normally open A15 = REL5, common
A16 = REL5, normally closed
A17 = REL5, normally open
Power supply
N.C.
Common
N.O.
REL 1
NOTE!
Common pin needs to be wired. Normally, power supply needs to
be connected according to the schematic to the right.
N.C.
ATTENTION! N.O. Common
After assembly make sure you tighten the housing screws with 0,8 Nm
to avoid any water ingression. REL 2