Page 77 - Schroeder - Hydraulic And Lube Filtration
P. 77
Manifold Mounted Pres sure Filter RFS50
Type Fluid Appropriate Schroeder Media Fluid NF30
®
Petroleum Based Fluids All E media (cellulose) and Z-Media (synthetic) Compatibility NFS30
High Water Content All Z-Media (synthetic)
®
Invert Emulsions 10 and 25 µ Z-Media (synthetic) YF30
®
®
Water Glycols 3, 5, 10 and 25 µ Z-Media (synthetic)
®
Phosphate Esters All Z-Media (synthetic) with H (EPR) seal designation CFX30
Skydrol ® 3, 5, 10 and 25 µ Z-Media (synthetic) with H.5 seal designation (EPR seals and Skydrol is a registered
®
®
stainless steel wire mesh in element, and light oil coating on housing exterior) trademark of Solutia Inc. PLD
Element Element selections are predicated on the use of 150 SUS (32 cSt) Element DF40
Pressure Series Part No. petroleum based fluid and a 40 psi (2.8 bar) bypass valve. Selection
Based on CF40
E 8R3 8R3 Flow Rate
Media 8R10 8R10 PF40
To 8RZ1 8RZ1
5000 psi 8RZ3 8RZ3 RFS50
(345 bar) Z- 8RZ5 8RZ5
Media ® RF60
8RZ10 8RZ10
8RZ25 8RZ25 CF60
gpm 0 10 15 20 25 30
Flow
(L/min) 0 50 75 100 115 CTF60
Shown above are the elements most commonly used in this housing.
Note: Contact factory regarding use of E Media in High Water Content, Invert Emulsion and Water Glycol VF60
Applications. For more information, refer to Fluid Compatibility: Fire Resistant Fluids, pages 19 and 20.
LW60
∆P housing ∆P element Pressure KF30
RFS50 ∆P housing for fluids with sp gr = 0.86: ∆P element = flow x element ∆P factor x viscosity factor Drop
Information
El. ∆P factors @ 150 SUS (32 cSt):
Based on TF50
8R3 .35 Flow Rate
8R10 .30 and Viscosity KF50
8RZ1 .87
8RZ3 .43 KC50
8RZ5 .39
8RZ10 .36 MKF50
8RZ25 .11
If working in units of bars & L/min, divide above KC65
factor by 54.9.
Viscosity factor: Divide viscosity by 150 SUS (32 cSt). NOF30-05
sp gr = specific gravity
NOF50-760
Sizing of elements should be based on element flow information provided in the Element Selection chart above.
FOF60-03
Notes ∆P filter = ∆P housing + ∆P element
Exercise: NMF30
Determine ∆P at 15 gpm (57 L/min) for
RFS508R10OD5 using 200 SUS (44 cSt) fluid.
RMF60
Solution:
∆P housing = 5.0 psi [.38 bar] Cartridge
∆P element = 15 x .30 x (200÷150) = 6.0 psi Elements
or
= [57 x (.30÷54.9) x (44÷32) = .41 bar]
∆P total = 5.0 + 6.0 = 11.0 psi HS60
or
= [.38 + .41 = .79 bar] MHS60
KFH50
SCHROEDER INDUSTRIES 75