Page 22 - Parker - AC30 Variable speed drive
P. 22

AC30 Variable Speed Drive
            Accessories and Options

            Ancillary Parts






            Three Phase Reactors
            Line reactors have been selected for the AC30 series to add inductance to reduce
            the harmonic content of the supply current.


                             Motor Power
            Order Code       Normal Duty       Inductance        Current
                               [HP/kW]           [mH]             [A rms]
                                1.5/1.1
            CO470651                              6.5              4
                                2.0/1.5
                                3.0/2.2
            CO352782                               5               8
                                4.0/3.0
            CO470652            5.0/4.0            3               8
            CO352783            7.5/5.5           2.5              12
            CO352785            10/7.5            1.5              18
            CO352786            15/11             1.2              25
                                20/15
            CO352901                              0.8              35
                                25/18
            CO352902            30/22             0.7              45
            CO352903            40/30             0.5              55
                                50/37
            CO352904                              0.4              80
                                60/45
            CO352905            75/55             0.3             100
            CO352906            100/75            0.2             130



            EMC Filters
            A range of custom designed optional EMC (Electromagnetic Compatibility) filters are
            available for use with the Parker SSD Drives product range. They are used to help
            achieve conformance with the EMC directive BS EN 61800-3:2004 - "Adjustable
            speed electrical power drive systems Part 3".
                                  Motor Power
            Order Code            Normal Duty       Frame Size
                                    [HP/kW]
                                     1.5/1.1            D
                                     2.0/1.5            D
                                     3.0/2.2            D
                                     4.0/3.0            D
            CO501894
                                     5.0/4.0            D
                                     7.5/5.5            D
                                     10/7.5             E
                                     15/11              E
                                     20/15              F
            CO501895                 25/18              F
                                     30/22              G
                                     40/30              G
            Consult Factory
                                     50/37              G
                                     60/45              H
            Consult Factory          75/55              H
                                     100/75             H

                                                               22