Page 17 - Clippard - Air Preparation Equipment
P. 17
®
MAXIMATIC STACKING FILTER-REGULATORS ®
Flow Rate vs. Set Point Pressure @ 100 psig Supply Pressure
MMFRS-1 Series
100
• Find the required flow rate in the graphs below.
80
• Determine the desired set point pressure.
Set Point Pressure (psig) 40
• With a suggested pressure drop of <15 psig,
determine which Filter-Regulator size provides 60
the required flow rate.
20
0
0 1 2 3 4 5
Flow Rate (scfm)
MMFRS-2 Series MMFRS-3 Series
100
80
Set Point Pressure (psig) 60
40
20
0
0 10 20 30 40 0 20 40 60 80 100
Flow Rate (scfm) Flow Rate (scfm)
MMFRS-4 Series MMFRS-5 Series
100
80
Set Point Pressure (psig) 60
40
20
0
0 50 100 150 200 0 70 140 210 280
Flow Rate (scfm) Flow Rate (scfm)
Clippard Instrument Laboratory, Inc. 877-245-6247 www.clippard.com 358