Page 572 - Wago_AutomationTechnology_Volume3_2015_US.pdf
P. 572

761-214

   9    TO-PASS  Compact, 8 AI, ELog, DLog
                   ®
  570   Telecontrol module for fault detection/indication, monitoring and remote control









                                                                                       Com
                                                                                       Busy
                                                                                       Run


                                                                               SIM    Status    PC           <_____________________________________ 105 mm/4.12 in _____________________________________>

                                                                    TO-PASS  ®










                                                                <________________________________________ 109 mm/4.29 in ________________________________________>


        Universal telecontrol module for fault detection/indication and monitoring of   Operating voltage ranges from +10V to 30VDC.
        machines and installations over a GSM network. The module can be used in
        many countries via an integrated quad-band GSM modem. Messages are sent  Special functions:
        via SMS, e-mail, fax or phone call. An integrated event logger creates the   • Acknowledgment: Acknowledging any fault message
        process image of all occurring events and stores all digital and analog values   • Stand-by: Automatic remote switching of the stand-by service
        available at the telecontrol module. The data memory stores up to 4096   • Remote parametrization: Programming and remote control conveniently
        process images in an adjustable cycle time. Switching of outputs is performed   performed from the office
        via SMS.                                            • Event logger: Saves all occurring status changes
        8 digital inputs, 8 analog inputs, 4 digital outputs and 2 analog outputs with   • Data logger: Saves all process values with adjustable cycle
        integrated GSM modem. Ideal for applications in distributed stations for tem-
        peratures ranging from -20°C to +70°C. Ability to mount on DIN-rail and
        intuitive user software make unit easy to handle.

        Description                  Item No.        Pack.    Technical Data
                                                     Unit
             ®
        TO-PASS  Compact, 8 AI, ELog, DLog  761-214  1        Digital inputs:
                                                                Number of inputs       8 (Type 3)
                                                                Input current          max. 2.9 mA at 30 V DC
                                                                Signal voltage (0)     0 V ... 5 V DC
        Accessories                  Item No.                   Signal voltage (1)     7 V ... 30 V DC
                                                              Analog inputs:
        Antennas, USB adapter and power supply   see pages 576 ... 577  Number of inputs  8 (0/4 mA ... 20 mA)
        units                                                   Internal resistance    approx. 200 Ω / 20 mA
        TO-PASS  Configuration Software  see Section 1          Measuring error (25 °C)  < ± 1 % of the full scale value
             ®
                                                                Temperature coefficient  < ± 0.1 % / K of the full scale value
        Approvals                                             Digital outputs:
                                                                No. of outputs         4 contacts
        Approvals                 for all EU countries          Output current (max.)  0.5 A/ 30 V DC, short-circuit protected
                                  Approvals for other countries on request  Analog outputs:
        r UL 508                                                No. of outputs         2 (0/4 mA ... 20 mA)
                                                                Load impedance         ≤ 600 Ω
        Technical Data                                          Measuring error (25 °C)  < ± 1 % of the full scale value
                                                                Temperature coefficient  < ± 0.1 % / K of the full scale value
        Operating temperature     -20 °C ... +70 °C           Communication            GSM quad-band
        Type of mounting          DIN 35 rail                 Communication types      SMS (bidirectional),
        Antenna connection        SMA                                                  telecommunication dial-up connection
        Wire connection           Terminal strips (WAGO 250 Series)                    (CSD)
                                  with push-wire connection   Signaling                3 LEDs for operating status indication
        Cross sections            0.5 mm² ... 1.5 mm² / AWG 22 ... 14  Operating voltage  +10 V ... +30 V DC
        Strip lengths             9 mm /0.35 in               Closed current           approx. 20 mA at +24V operating voltage
        Dimensions (mm) W x H x L  109 x 78 x 105             Current during transmission  < 500 mA at +24V operating voltage
        Weight                    412 g
        Storage temperature       -40 °C ... +85 °C
        Degree of protection      IP20
        EMC immunity of interference  acc. to EN 61000-6-2
        EMC emission of interference  acc. to EN 61000-6-3
   567   568   569   570   571   572   573   574   575   576   577