Page 8 - Parker - L90LS Mobile directional control valve canadian build program
P. 8
Work Section Ordering Information
Valve Section Compensator
Series Type Spool Operator Voltage Override Port A Port B Port A Port B
L90 - TTT - MBX - K - EC - 12D - H - - - -
TOO - Compensator, No Port RV or LS RV Omit - Not machined*
TOT - Compensator, Port RV, No LSRV N - LS Relief Ports Plugged
TTT - Compensator, Port RV, LSRV Y - Adjustable LS Reliefs
* Cannot be combined with TTT section
Spools - See Spool Chart
Omit - Not machined*
KL - KL Compensator (6 bar) Y2 - Port RV Plugged
K - K Compensator (10 bar) N2 - Anti-Cav Check
KH - KH Compensator (16 bar) X2 - Open to Tank
LC - Load Check (w/o Compensator) 25 - 363 PSI RV
32 - 465 PSI RV
CH - Manual (Spring Centre)* 50 - 725 PSI RV
CD - Manual (3-pos Detent)* 63 - 910 PSI RV
PC - Hydraulic Operator 80 - 1,160 PSI RV
EC - Solenoid Operator 100 - 1,450 PSI RV
EX1 - ATEX Solenoid Operator, ODD Section 125 - 1,810 PSI RV
EX2 - ATEX Solenoid Operator, EVEN Section 140 - 2,030 PSI RV
* Must use H Override option 160 - 2,320 PSI RV
X - No Solenoids* 175 - 2,535 PSI RV
12D - Double Solenoid pilot, 12VDC Deustch (PS25)** 190 - 2,750 PSI RV
12S - Single Solenoid pilot, 12VDC Deustch (PS25)** 210 - 3,045 PSI RV
24D - Double Solenoid pilot, 24VDC Deustch (PS25)** 230 - 3,335 PSI RV
24S - Single Solenoid pilot, 24VDC Deustch (PS25)** 240 - 3,480 PSI RV
E24D - Double ATEX Solenoid pilot, 24VDC*** 250 - 3,625 PSI RV
E24S - Single ATEX Solenoid pilot, 24VDC*** 260 - 3,770 PSI RV
* Not available with option EC, EX1 or EX2 270 - 3,915 PSI RV
** Available with EC operator only
280 - 4,060 PSI RV
*** Available with EX1 & EX2 only
300 - 4,350 PSI RV
H - Handle Override 320 - 4,640 PSI RV
P - Manual Override w/o Handle* 350 - 5,075 PSI RV
X - No Handle Override* * Cannot be combined
with TOO section
* Not available with option CH or CD
8