Q2 adsorption dryer mounted on compressor








































                                             Model OF1202-40BQ3 mounted with a dryer









          After being cooled, the air enters   Following the filtration stage, air   The dryer is controlled by a
          the dryer through a shuttle valve   passes through the desiccant bed   PLC which periodically switches
          and is directed into one of the    where any remaining moisture is     the solenoid valves when the
          desiccant columns. Each column     adsorbed by the desiccant beads.    compressor is running, reversing
          contains a unique desiccant                                            the function of each column and
          cartridge which incorporates inlet   After drying, the air passes through   therefore ensuring the continuous
          and outlet filtration.             particle filter, which retains any   supply of clean and dry air.
                                             remaining desiccant particles that
          Bulk liquids (water) and particles are   may have been carried through the
          removed by the filtration/separation   system (<1 µm ISO 8573.1 class
          stage which is located on the inlet   2 dust). Simultaneously, a small
          to the cartridge. Water is retained   amount of dry air is counter-flowed
          in a “quiet zone” until the column is   down through the other cartridge
          regenerated (when it will be vented   and exhausted to atmosphere,
          to atmosphere as the column is     removing the moisture and thus
          depressurized).                    regenerating that desiccant column.