Page 16 - Parker - Flow Control Valves
P. 16
Catalog HY15-3502/US Needle Valve
Technical Information Series FV101 and FV102
CV
General Description
Needle Valve with a Reverse Check. Also known as a
FV101
Flow Control Valve. For additional information see
Valves
Check
SH Technical Tips on pages FC1-FC4.
Features
Shuttle
Valves
LM • Hardened, precision ground parts for durability
• Compact size for reduced space requirements
• Fine thread needle option available for precise (2)
adjustment Metered Flow
Inlet
Controls
Load/Motor
FC • All external parts zinc plated Free Flow
(2) (1) Outlet
(1)
Free Flow Inlet
Metered Flow Outlet
Controls
Flow
PC Metered Flow
Free Flow
Pressure
Controls
FV102
LE
Specifications
Free Flow
Inlet
Rated Flow FV101 45 LPM (12 GPM) (1)
Metered
FV102 23 LPM (6 GPM) Flow Outlet
Elements
Logic
DC (2)
Maximum Inlet 210 Bar (3000 PSI) Metered Flow Inlet
Free Flow Outlet
Pressure
Cartridge Material All parts steel. All operating
Directional
Controls
MV parts hardened steel.
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon) Dimensions Millimeters (Inches)
Manual
Valves
SV (-25°F to +250°F)
Fluid Mineral-based or synthetic with Screw and 38.1 (1.50)
Compatibility/ lubricating properties at viscosities Knob Adjust - Dia. Knob
Viscosity of 45 to 2000 SSU (6 to 420 cSt) 1/4" Internal Hex.
Valves
Solenoid
PV
Filtration ISO Code 16/13, 1" Hex.
SAE Class 4 or better 22 Nm 38.1
(16 lb. ft.) (1.50)
Approx. Weight .23 kg (0.5 lbs.) Torque 18.8
Proportional
Valves
(.74)
CE
7/8-14 UNF-2A
Cavity C10-2 Thread
(See BC Section for more details)
6.4 31.7
Form Tool Rougher None (.25) (1.25)
Electronics
Coils &
BC Finisher NFT10-2F (2)
(1)
Ø 15.8
(.62)
Bodies &
Cavities
TD
Data
Technical
FC15 Parker Hannifin Corporation
Hydraulic Cartridge Systems