Page 20 - Parker - Flow Control Valves
P. 20

Catalog HY15-3502/US                              P.C. Flow Regulator Valve
                   Technical Information                             Series FR101

            CV
                   General Description
                   Pressure Compensated Flow Regulator Valve.
                   NOTE: When used with a fixed displacement pump,
              Check
            Valves
            SH     pressure to the cartridge must be controlled by a relief
                   valve located between the pump and the FR101
                   cartridge. For additional information see Technical Tips
                   on pages FC1-FC4.
            Valves
              Shuttle
            LM     Features
                   •  Hardened, precision ground parts for durability
                   •  Cartridge design
                   •  Acts as a fixed orifice in reverse flow condition
              Load/Motor
            Controls
            FC                                                          Inlet          Outlet
                   •  All external parts zinc plated                    (1)             (2)
                                                                                                                Reg.
                                                                                                                (2)
            Controls
              Flow
            PC                                                              Adjustable Style          Inlet
                                                                                                       (1)


              Pressure
            Controls
            LE     Specifications                                      Performance Curves
                                                                       Regulated Flow vs. Pressure
                    Rated Flow        Fixed     22.5 LPM (6 GPM)       (Through cartridge only)
                                      Adjusted  26.5 LPM (7 GPM)
              Logic
            Elements
                                                                         GPM LPM       Hydraulic Oil 150 SSU @ 100°F (32 cSt)
            DC
                    Maximum Inlet     245 Bar (3500 PSI)                  7  26.3
                    Pressure
                                                                          6  22.5
                                                                                      22.5 LPM (6 GPM) Fixed  16.7 LPM (4.45 GPM)
                    Accuracy (Fixed)  3.8 LPM (1 GPM) ±20%                5  18.8                        Adjustable (Max. Range)
              Directional
            Controls
                                      7.5 - 11.3 LPM (2-3 GPM) ±15%
            MV
                                      15 - 22.5 LPM (4-6 GPM) ±10%        4  15.0                        16.7 LPM (4.45 GPM)
                    Adjustment Range  ±30% Nominal                      Regulated Flow  3  11.3  11.3 LPM (3 GPM) Fixed  Adjustable (Min. Range)
                    (Adj. Version)                                        2  7.5
            Valves
              Manual
            SV
                    Cartridge Material  All parts steel. All operating                3.8 LPM (1 GPM) Fixed
                                                                          1  3.8
                                      parts hardened steel.
                                                                           0
                    Operating Temp.   -40°C to +93.3°C (Nitrile)             Bar 0        68         138        207
            Valves
              Solenoid
                    Range/Seals       (-40°F to +200°F)                      PSI         1000        2000       3000
            PV                                                                                Inlet Pressure
                                      -31.7°C to +121.1°C (Fluorocarbon)
                                      (-25°F to +250°F)
                                                                         GPM LPM       Hydraulic Oil 150 SSU @ 100°F (32 cSt)
                                                                          7  26.3
                    Fluid             Mineral-based or synthetic with
            Valves
              Proportional
                    Compatibility/    lubricating properties at viscosities  6  22.5
            CE      Viscosity         of 45 to 2000 SSU (6 to 420 cSt)    5  18.8
                                                                        Regulated Flow
                    Filtration        ISO Code 16/13,                     4  15.0
                                      SAE Class 4 or better
              Coils &
            Electronics
            BC                                                            3  11.3
                    Approx. Weight    .23 kg (0.5 lbs.)                   2  7.5
                    Cavity            No. C10-2
                                      (See BC Section for more details)   1  3.8
            Cavities
              Bodies &
            TD                                                             0
                    Form Tool         Rougher   None                         Bar      7     14     22    28     35    42
                                                                               0
                                      Finisher  NFT10-2F                     PSI     100    200   300    400   500    600
                                                                                        Minimum Operating Pressure
            Data
              Technical
                                                                   FC19                        Parker Hannifin Corporation
                                                                                               Hydraulic Cartridge Systems
   15   16   17   18   19   20   21   22   23   24   25