Page 20 - Parker - Flow Control Valves
P. 20
Catalog HY15-3502/US P.C. Flow Regulator Valve
Technical Information Series FR101
CV
General Description
Pressure Compensated Flow Regulator Valve.
NOTE: When used with a fixed displacement pump,
Check
Valves
SH pressure to the cartridge must be controlled by a relief
valve located between the pump and the FR101
cartridge. For additional information see Technical Tips
on pages FC1-FC4.
Valves
Shuttle
LM Features
• Hardened, precision ground parts for durability
• Cartridge design
• Acts as a fixed orifice in reverse flow condition
Load/Motor
Controls
FC Inlet Outlet
• All external parts zinc plated (1) (2)
Reg.
(2)
Controls
Flow
PC Adjustable Style Inlet
(1)
Pressure
Controls
LE Specifications Performance Curves
Regulated Flow vs. Pressure
Rated Flow Fixed 22.5 LPM (6 GPM) (Through cartridge only)
Adjusted 26.5 LPM (7 GPM)
Logic
Elements
GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)
DC
Maximum Inlet 245 Bar (3500 PSI) 7 26.3
Pressure
6 22.5
22.5 LPM (6 GPM) Fixed 16.7 LPM (4.45 GPM)
Accuracy (Fixed) 3.8 LPM (1 GPM) ±20% 5 18.8 Adjustable (Max. Range)
Directional
Controls
7.5 - 11.3 LPM (2-3 GPM) ±15%
MV
15 - 22.5 LPM (4-6 GPM) ±10% 4 15.0 16.7 LPM (4.45 GPM)
Adjustment Range ±30% Nominal Regulated Flow 3 11.3 11.3 LPM (3 GPM) Fixed Adjustable (Min. Range)
(Adj. Version) 2 7.5
Valves
Manual
SV
Cartridge Material All parts steel. All operating 3.8 LPM (1 GPM) Fixed
1 3.8
parts hardened steel.
0
Operating Temp. -40°C to +93.3°C (Nitrile) Bar 0 68 138 207
Valves
Solenoid
Range/Seals (-40°F to +200°F) PSI 1000 2000 3000
PV Inlet Pressure
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)
7 26.3
Fluid Mineral-based or synthetic with
Valves
Proportional
Compatibility/ lubricating properties at viscosities 6 22.5
CE Viscosity of 45 to 2000 SSU (6 to 420 cSt) 5 18.8
Regulated Flow
Filtration ISO Code 16/13, 4 15.0
SAE Class 4 or better
Coils &
Electronics
BC 3 11.3
Approx. Weight .23 kg (0.5 lbs.) 2 7.5
Cavity No. C10-2
(See BC Section for more details) 1 3.8
Cavities
Bodies &
TD 0
Form Tool Rougher None Bar 7 14 22 28 35 42
0
Finisher NFT10-2F PSI 100 200 300 400 500 600
Minimum Operating Pressure
Data
Technical
FC19 Parker Hannifin Corporation
Hydraulic Cartridge Systems