Page 28 - Parker - Flow Control Valves
P. 28
Catalog HY15-3502/US P.C. Flow Control Valve
Technical Information Series FC101
CV
General Description
Pressure Compensated Flow Control. For additional
information see Technical Tips on pages FC1-FC4.
Valves
Check
SH
Features
• Hardened, precision ground parts for durability
Shuttle
Valves
LM • Compact size for reduced space requirements
• Free flow in reverse condition
• All external parts zinc plated
Controls
Load/Motor
(2)
FC Metered Flow
(1) (2) Outlet
Free Flow
Inlet
(1)
Full Flow Outlet
Flow
Controls
Metered Flow Inlet
PC
Pressure
Controls
LE Specifications Performance Curves
Regulated Flow vs. Pressure Drop
Rated Flow 20.6 LPM (5.5 GPM) (Through cartridge only)
GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Elements
Logic
DC 8 30
Maximum Inlet 210 Bar (3000 PSI)
Pressure
6 23 600
Cartridge Material All parts steel. All operating
Controls
Directional
parts hardened steel. 500
MV Regulated Flow 4 15 400
Operating Temp. -40°C to +93.3°C (Nitrile)
Range/Seals (-40°F to +200°F) 300
-31.7°C to +121.1°C (Fluorocarbon) 2 8 200
Valves
Manual
(-25°F to +250°F)
SV 100
050
Fluid Mineral-based or synthetic with 0
Compatibility/ lubricating properties at viscosities Bar 0 35 70 105 140 170 204
Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI 500 1000 1500 2000 2500 3000
Pressure Drop ( P)
Valves
Solenoid
PV
Filtration ISO Code 16/13, Pressure Drop vs. Flow (Through cartridge only)
SAE Class 4 or better
PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
250 18
Approx. Weight .23 kg (0.5 lbs.)
Valves
Proportional
CE 200 14
Cavity C10-2 P)
(See BC Section for more details)
Form Tool Rougher None 150 11
Electronics
Coils &
Finisher NFT10-2F Pressure Drop (
BC 100 7
50 4
Cavities
Bodies &
0
TD LPM 8 15 23 30
0
GPM 2 4 6 8
Flow (Q)
Data
Technical
FC27 Parker Hannifin Corporation
Hydraulic Cartridge Systems