Page 36 - Parker - Instrumentation process analyzer condensed catalog
P. 36

FS190 Series                                                       316L SS, Excess Flow
                                                                                           Shut-Off Valve

                Product Features & Benefits



                                               •  Offered with 6 different      •  Actuating knob designed
                                                  pressure/flow limits.           to manually operate valve
                                                                                  and clearly indicate relative
                                               •  Differential pressure that is   operating position - Open
                                                  created is not affected by      (Reset) or Auto (Shut off).
                                                  mounting orientation (non-
                                                  attitude sensitive).          •  Pneumatic actuator available
                                                                                  to reset the valve remotely.
                                               •  Cleaned for O  service.
                                                              2







                Operating Conditions
                Temperature        -10°F to 150°F (-23°C to 66°C)
                Supply Pressure    Based upon Flow Limit Setting
                    A - D Flow     10 psig to 3,500 psig (0.7 barg to
                    Limits:        241 barg)
                                   20 psig to 3,500 psig (1.4 barg to
                    E - F Flow Limits:
                                   241 barg)
                Differential Pressure  5 psig or 12 psig (0.3 barg or 0.8
                                   barg)
               *  For detailed information on Materials of Construction, visit us at
                 www.parker.com/veriflo to review the complete product literature sheet.
               Ordering Information



                                                 1           2            3           4
                        Sample:  FS190           S           A         FSFM         AOP
                   Finished Order:  FS190SAFSFMAOP


                 1
                     Material                               4  Optional Features
                 S  =  316L Stainless Steel                    This section can have multiple options
                                                          AOP = Air Operated
                 2
                     Flow Limit Setting                   EX  = 10 Ra microinch Finish (not available with P Connection Option)
                     Nominal Flow Limit at:               TH  = Hastelloy C-22® Trim Internals (Includes compression
                    1000 psig Inlet       30 psig Inlet         member, poppet, spring and orifice)
                 A    =   4.8 SLPM         0.4 SLPM       3.46  = FLV 110 Dimensional Replacement (3.46” end-to-end
                                                                dimensions)
                 B    =   9.1 SLPM         1.7 SLPM       3.70  = FLV 120 Dimensional Replacement (3.70” end-to-end
                 C    =  21.8 SLPM         3.9 SLPM             dimensions)
                 D    =  39.5 SLPM         9.0 SLPM       5.25  = 5.25” end-to-end dimensions
                 E    =  72.3 SLPM        14.4 SLPM       5.75  = 5.75” end-to-end dimensions
                 F    =  120.6 SLPM       22.5 SLPM

                  3  Connection (Inlet & Outlet)
                 P     =  1/4” NPTF
                 FSMM  =  1/4” FS Male In, Male Out
                 FSFF  =  1/4” FS Female In, Female Out
                 FSFM  =  1/4” FS Female In, Male Out
          36     FSMF  =  1/4” FS Male In, Female Out
                 TS    =  1/4” Welded Tube Stubs
   31   32   33   34   35   36   37   38   39   40   41