Page 39 - Parker - Instrumentation process analyzer condensed catalog
P. 39

LC223S Series                                            Gas or Liquid Flow Controller
                                                                               316L SS, High Pressure,


               Product Features & Benefits



                                               •  Repeatability:  Flow is       •  Wide Flow Range:  From
                                                  stable within ±0.2% of flow     25scc/m to 40 slpm.
                                                  value under the following
                                                  conditions:                   •  Wide Pressure Range:  From
                                                   1.   Ambient temerature        200 to 5000 psig (14 to 345
                                                       varies no more than        barg).
                                                       10°F.
                                                                                •  Corrosion resistant.
                                                   2.   Inlet pressure remains
                                                       constant.
                                                   3.   Downstream pressure
                                                       does not vary by more
                                                       than 70% of established
                                                       value.




                Operating Conditions                              Functional Performance
                Maximum Inlet      5,000 psig (345 barg)                             25 sccm to 40 slpm
                Maximum Dome                                      Flow Range         Established by Customer supplied
                Pressure           5,000 psig (345 barg)                             flow restriction device
                Required Differential                             Internal Volume
                Pressure           200 psig (14 barg)                    Dome        2.0 cc
                Temperature        -20°F to 200°F (-29°C to 93°C)        Body        2.1 cc
                                                                  *  For detailed information on Materials of Construction, visit us at
                                                                   www.parker.com/veriflo to review the complete product literature sheet.












                Ordering Information




               LC223S Part Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54018192




                                                  EXAMPLE APPLICATION

                                                                1500 PSI
                                                                CAP PORT

                                                     OUT        IN
                                SYSTEM SET                       FLOW RESTRICTOR     1500 PSI
                                @ 500 PSI                 LC223S
                                                                      VALVE
                                                                     OR MFC
                                                                                                                39