Page 73 - Parker - Gearheads and Gearmotors
P. 73
8) Determine Thermal (KT) and Shock (KS) Factor 9) Confirm Selection
Use the selected gearhead’s specifications and the K Using the selected gearhead’s listed specifications
Factor charts below to compensate for thermal and and the calculations from the previous steps, check Design Reference
shock torque effects to comply with the following: that the following criteria are met:
For continuous duty: T nom r > (T mean )(K )(K ) • T accr must be greater than the larger of T acc or T dec
T
S
• Check the emergency stop torque rating
For intermittent duty: T nom r > (T mean )(K )
S
• N nomr must be greater than N mean i
K Thermal Factor • N maxr must be greater than N max i
T
This factor derates the transmitted torque to prevent • Verify radial and axial shaft load
case temperature from exceeding 100°C. The KT If any of the above comparisons are not met, then:
values shown in the table below are for 25°C ambient • Choose a larger gearhead
temperature, medium-size indoor space, with the • Reevaluate the ratio
gearheads mounted to a metal base with a surface • Reevaluate the torque
area more than 3 times larger than the gearhead • Reevaluate the speed
surface area. • Reevaluate the duty cycle
K Shock Factor • Reevaluate shaft load
S
This factor is used to derate the transmitted torque K Shock Factor
S
when the application is not well defined, has
random duty cycles or experiences varying peak Load Type Application KS
torques subjecting the gear teeth to torques above Known
the estimated torques. K factor values are shown Load Data All Industries 1.00
S
below for three general application categories. K S Unknown
values are independent of gearhead size. If your Load Data Textiles, liquid mixers, can filling, food, 1.25
conveyors, plastics, fans
application does not fit into one of these categories, – Light
contact Parker to discuss your requirements. Unknown
Load Data – Paper mills, rubber industry, sugar 1.50
Moderate industry, metal mills, lumber, robotics
K Thermal Factor
T
KT Factor @ Designated Output Speed (RPM)
Frame Size Ratio 100 200 400 600 800 1000 1500 2000 2500 3000
PV40 1 1 1 1 1 1 — — — —
PS, PX, PV, RS60 1 1 1 1 1 1 — — — —
PS, PX, PV, RS90 1 1 1 1 1 1.2 — — — —
PS, PX, RS115 1 1 1 1 1.2 1.5 — — — —
PS, RS142 1 1 1 1.3 1.7 — — — — —
1 stage (1) 1 1 1.5 2.3 — — — — — —
PS, RS180
2 stage (2) 1.1 1.5 — — — — — — — —
1 stage (1) 1 1.2 2.1 3.2 — — — — — —
PS, RS220
2 stage (2) 1.3 2.5 — — — — — — — —
1 stage (1) 1 1.5 3.1 — — — — — — —
PS ,RS300
2 stage (2) 1.9 — — — — — — — — —
1 1 1 1 1 1 1 1 1 1.25 1.5
RT, RD, RB90
2-30 1 1 1 1 1 1 1.1 — — —
1 1 1 1 1 1 1 1 1.3 1.7 —
RT, RD, RB115
2-30 1 1 1 1 1 1.3 2 — — —
1 1 1 1 1 1 1.3 2 2.7 3.4 —
RT, RD, RB142
2-30 1 1 1 1 1.3 1.6 — — — —
1 1 1 1 1 1.3 1.7 2.5 3.4 — —
RT, RD, RB180
2-30 1 1 1 1.4 1.8 2.3 — — — —
1 1 1 1.2 1.8 2.4 3.0 4.5 — — —
RT, RD, RB220
2-30 1 1 1.3 2.0 2.6 — — — — —
(1) Data given for PS 3:1 to 10:1 and all RS ratios
(2) Data given for PS ratios above 10:1
Parker Hannifin Corporation • Electromechanical Automation Division • 800-358-9070 • www.parkermotion.com 73