Page 21 - Eaton - Gas/Liquid separators
P. 21

Gas/Liquid   Separation  Fabricated    Construction
                 Gas/Liquid Separators
                Series CLC




                Coalescer/Separator                                           Type 35-L
                                                                                Type 31L-CLC for Horizontal
                                                                              with Side
                                                                                or Vertical Applications
                                                                              Inlet for
                                                                              Vertical
                                                                              Upflow





      •  Centrifugal In-line Gas/Liquid Separators

      •  Two-Stage Design for Maximum Efficiency


      • Flanged Connections                                       High-Efficiency Separation    Two-Stage Separation
                                                                  Down to 4 Microns
                                                                                             In the first stage, the
      • Carbon Steel or Stainless Steel Construction              The unique two-stage       coalescer stage, smaller liquid
                                                                                             droplets enter a special wire
                                                                  design of these Series CLC
                                                                  Coalescers/Separators allows   mesh de-misting pad in the
      • Horizontal or Vertical Flow                               them to remove 99% of all   vessel. The pad’s purpose is
                                                                                             to increase the size of the
                                                                  liquid and solid particles
                                                                  larger than 4 microns in size.   droplets as they pass through
       FEATURES                                                   Standard, one-stage separators   it so they can be removed.
                                                                  are only capable of removing   The larger liquid droplets
       •  Removes 99% of Liquid and Solid                         particles larger than 10 microns   exit the de-misting pad and
         Entrainment Particles Larger Than 4 Microns              in size. The efficiency of   enter the second, separation
       •  Easy Maintenance                                        Eaton’s Coalescer/Separator   stage. In the second stage,
       •  Three Flow Configurations                               far exceeds that of any other   the droplets are centrifugally
                                                                                             thrown to the outside wall
                                                                  type of centrifugal, cyclone,
       •  Gas, Steam, or Air Applications                         turbine or vane type separator.   of the vessel by a unique
       •  High Efficiency Over Wide Flow Range                    And it works with no moving   Cenpellar™ and flow to the
                                                                  parts to fail or wear out.  bottom for draining. Eaton’s
                                                                                             Vortex Containment Plate
       OPTIONS                                                    Applications               (VCP) prevents the droplets
                                                                                             from being re-entrained after
       •  ASME Code Stamp                                         The Eaton Coalescer/Separator   separation.
                                                                  provides two-stage separation
                                                                  of liquid that is in the form of
                              Type 35L-CLC                                                   Easy Maintenance
       Type 36L-CLC           with                                a fine mist or fog from a gas   The only maintenance required
       with Vertical          side                                or vapor. The Coalescer/
       Upflow Inlet and       Inlet for                           Separator is primarily used in   is the inspection, cleaning, or
       Horizontal Outlet      Vertical                            applications where a fine mist   replacement of the de-misting
                              Upflow                              is encountered in processes   pad. This is easily accomplished
                                                                  involving cooling, condensation,   through either a quick-opening
                                                                  flashing, or evaporation, such as:  body closure or body flanges.
                                                                  •  Compressed refrigeration
                                                                    gases                    Engineering Specifications
                                                                  •  Evaporator overhead steam  All gas/liquid separators are
                                                                                             fabricated carbon steel or
                                                                  •  Compressed air prior to   stainless steel construction
                                                                    desiccant dryer beds     with two-stage coalescer/
                                                                  •  High-pressure gas at    separator design and flanged
                                                                    injection wells          connections. Separators have
                                                                                             an ASME Code Stamp.
                                                                  •  Fuel gas lines to engines
                                                                    in power
                                                                  •  Industrial plants
                                                                  •  Natural gas and gas
                                                                    distribution lines
                                                                  •  Regulator stations
   16   17   18   19   20   21   22   23   24   25   26