Page 36 - Eaton - Gas/Liquid separators
P. 36

ENGINEERING SPECIFICATIONS
                      Gas/Liquid Separators






      Type T, ST or STH           Type 31L-ST Gas/Liquid     Type CLC                   Exhaust Heads
      Gas/Liquid Separators       Separators                 Coalescer/
                                                             Separators                 All exhaust heads shall be (cast
      All gas/liquid separators   All gas/liquid                                        iron), (fabricated carbon steel,
      shall be constructed of     separators                 All gas/liquid             stainless steel or other alloy)
      (iron, carbon steel,        shall be cast              separators                        construction with
      stainless steel or other    iron construc-             shall be of fabricated (carbon steel   (threaded or flanged)
      alloy) with threaded,       tion with (threaded or     or other alloy) construction with   piping connections for
      flanged, or socket weld connec-  flanged) piping connections for   flanged connections for pipe   pipe size___. Exhaust
      tions for pipe size___. Construction   pipe size ___. Separators will   size___. Separators will have a   heads will remove 99%
      shall be (cast, fabricated).   remove 99% of all entrained liquid   two-stage coalescer/separator   of all entrained liquid or
      Separators will remove 99% of   or particulate matter 10 micron in   design and remove 99% of all   particulate matter 10 micron in
      entrained liquid or particulate   size or larger when properly   liquid and particulate matter 4   size or larger when properly
      matter 10 micron in size or larger   installed. Separators to incorpo-  micron in size or larger when   installed. All exhaust heads will be
      when properly installed.    rate a Cenpellar™ for efficient   properly installed. Separators to   designed so that there will be no
      Re-entrainment of separated   operation and a Vortex   incorporate a de-mister pad and a   required maintenance and have a
      material will be prevented by a   Containment Plate to prevent   Cenpellar™ for efficient operation   Vortex Containment Plate to
      Vortex Containment Plate. Options   re-entrainment of separated   as well as a Vortex Containment   prevent the re-entrainment of
      required are (integral trap, trap   material. All separators shall have   Plate to prevent re-entrainment of   separated material. Exhaust heads
      heating element, ASME UM or U   an integral trap to save space and   separated material. Required   shall be Eaton Type 40EHC or Type
      Code Stamp, water gauge tap,   shall be capable of automatically   options are (ASME Code Stamp).   40EHMF.
      thermometer tap, larger drain   ejecting the condensate at    All Coalescer/Separators shall be
      size). Separators shall be Eaton   predetermined levels without loss   Eaton Type CLC, 31, 35 or 36.
      Type ( T, ST, STH).         of line pressure. Required options                    Float Drain Traps
                                  include (trap heater, ASME Code
                                  Stamp). Separators shall be    Type DTL Gas/Liquid    All float drain traps shall be cast
                                  Eaton Type 31L-ST.         Separators                 (iron or stainless steel) with stain-
                                                                                        less steel internal parts and
                                                             All gas/liquid separators   threaded connections for pipe size
                                        Type 10-R Series Gas/  shall be fabricated      ___. Traps to require no priming
      Type 30L Series Gas/Liquid        Liquid Separators    (carbon steel, stainless   and all internal parts should be
      Separators                                             steel or other alloy)      attached to and removable with
                                        All gas liquid separators   construction with   the cover without disconnection
      All gas/liquid separators shall be of   shall be fabricated (carbon   flanged connections for   the trap from the line. All traps
      fabricated (carbon steel, stainless   steel or other alloy)   pipe size___. Separators   shall have corrosion resistant
      steel or other alloy) with flanged   construction with flanged   will remove 99% of all   stainless steel, nonmagnetic
      connections for pipe size___.   connections for pipe size ___.   liquid or entrained   valves and seats. Traps to be
      Separators will remove 99% of   Separators will remove 99% of all   particulate matter 10 micron in   Eaton Model 90AC, 95AC, 230AC
      entrained liquid or particulate   entrained liquid or particulate   size or larger when properly   or 350AC.
      matter 10 micron in size or larger   matter 10 micron in size or larger   installed. Separators to be
      when properly installed. Separator   when properly installed.   specially designed to handle
      design shall incorporate a   Separators shall have a two-stage   larger than normal solid loads   Type 60-I and 70-I Internal
      Cenpellar™ for efficient operation.   design for separating large   and have a conical shaped   Separators
      Re-entrainment of separated   volumes of liquid and be capable   sump to better collect solids.
      material will be prevented by a   of handling liquid slugs.   Separators shall have a Vortex   All gas/liquid separators
      Vortex Containment Plate. Options   Re-entrainment of separated   Containment Plate to prevent   shall be of the internal
      required are (oversize inlet connec-  material will be prevented by a   re-entrainment of separated   design type and fabricated of
      tions, reduced size inlet and outlet   Vortex Containment Plate. All   material. All separators shall be   (carbon steel, stainless steel or
      connections, specified flow   separators will have an ASME   Eaton Type T-DTL, 33L-DTL, or   other alloy) with Type 304L stain-
      pattern, integral sump, ASME   Code Stamp. Required options are   31L-DTL.        less steel blades. Separators shall
      code stamp). Separators shall be   (support stand, multiple inlets/               remove 99% of all entrained liquid
      Eaton Type 30L Series.      outlets). Separators shall be Eaton                   or particulate matter 10 micron in
                                  Type 10-R Series standard or                          size or larger when properly
                                  compact.                                              installed. Separators shall have an
                                                                                        (upflow, down-flow) design config-
                                                                                        uration. Separators to be Eaton
                                                                                        Type 60-I or 70-I.




                                 North America       China                For more information, please     June 2014
                                 44 Apple Street     No. 3, Lane 280,     email us at filtration@eaton.com
                                 Tinton Falls, NJ 07724  Linhong Road
                                 Toll Free: 800 656-3344    Changning District, 200335    or visit www.eaton.com/filtration
                                 (North America only)  Shanghai, P.R. China  © 2014 Eaton. All rights reserved. All trademarks
                                 Tel: +1 732 212-4700  Tel: +86 21 5200-0099  and registered trademarks are the  property of their
                                                                          respective owners. All information and recommenda-
                                 Europe/Africa/Middle East                tions appearing in this brochure concerning the use of
                                 Auf der Heide 2                          products described herein are based on tests believed
                                 53947 Nettersheim, Germany  Singapore    to be reliable. However, it is the user’s responsibility
                                                     4 Loyang Lane #04-01/02
                                 Tel: +49 2486 809-0  Singapore 508914    to determine the suitability for his own use of such
                                                                          products. Since the actual use by others is beyond our
                                 Internormen Product Line   Tel: +65 6825-1668  control, no guarantee, expressed or implied, is made
                                 Friedensstraße 41                        by Eaton as to the effects of such use or the results to
                                 68804 Altlußheim, Germany                be obtained. Eaton assumes no liability arising out of
                                 Tel: +49 6205 2094-0  Brazil             the use by others of such products. Nor is the informa-
                                 Begerow Product Line  Av. Julia Gaioli, 474 –    tion herein to be construed as absolutely complete,
                                                                          since additional information may be necessary or
                                 An den Nahewiesen 24   Bonsucesso        desirable when particular or exceptional conditions or
                                 55450 Langenlonsheim, Germany  07251-500 – Guarulhos, Brazil  circumstances exist or because of applicable laws or
                                 Tel: +49 6704 204-0  Tel: +55 11 2465-8822  government regulations.
   31   32   33   34   35   36   37   38