82D40-2/82D63-5 Series


                                                                            Pneumatic Power Clamps | Dimensions


                                                                                                 82D40-223C900B


                                                   Dimensions of the
                                                     driven shaft     52
                                 ~125                                 B3
                                  117               SW                47
                                 107 ±0,05                          B1   B2
                                 73 ±0,02                L1           34                 F     F






                                                      ±0,05
                                           11         38             30 ±0,1
                                                  11 ±0,1  ±0,1  ~143        58,5
                                 35 ±0,2            65              (±0,05 f. ø8H7)
                                (±0,02 f. ø6H7)                                       Safety notice:
                     25 ±0,1  (±0,02 f. ø6H7)    M8  32 ±0,1  +0,1  55  0  97         The load on the clamping
                                                                                      arms must always point
                                                                             8 N9
                                                                                      direction. Single load of
                                 M6 ø6 H7      ø8 H7                        3,5 -0,2  towards the clamping
                                                                              0
                                                           ~275                       one arm is prohibited
                                                                                       Medium: air, max. 6 bar, operation
                                                                                       with oil-free air is permissible

                                           IMPORTANT!
                Connector socket           Power clamp must only
                and cable are not          be operated by external
                supplied with the unit.    pneumatic one-way flow
                                           control valves.
                                           G1/4



                                                                                                 82D63-523C900B









                                                                                               F     F









                                                                                            Safety notice:
                                                                                            The load on the clamping
                                                                                            arms must always point
               Connection M12x1; 4-channel                                                  towards the clamping
               The connector socket and the                                                   direction. Single load of
               cable are not supplied with the    Important!
               unit.                                                                        one arm is prohibited
                                                  Power clamp must only be
                                                  operated by external                      Medium: air, max. 6 bar, operation
                                                  pneumatic one-way flow                    with oil-free air is permissible
                                                  control valves.







            Dimensions and technical information are subject to change without notice  PC-PPC-62