Page 34 - Parker - The Handbook of Hydraulic Filtration
P. 34

Fluid Analysis



         Filtration Fact                     ▼ Patch Test

                                             ▼ Portable Particle Counter           content, and compared to known ISO
         The only way to know the            ▼ Laboratory Analysis                 standards. By using this comparison,
                                                                                   the user can get a “go, no-go” estimate
         condition of a fluid is                                                   of a system’s cleanliness level.
                                             Fluid analysis is an essential part of
         through fluid analysis.
                                             any maintenance program. Fluid analy-
         Visual examination is not           sis ensures that the fluid conforms to  Another lesser-used deviation of the
                                                                                   patch test would be the actual count-
         an accurate method.                 manufacturer specifications, verifies  ing of the particles seen under the
                                             the composition of the fluid, and deter-
                                                                                   microscope. These numbers would
                                             mines its overall contamination level.
         Filtration Fact                                                           then be extrapolated into an ISO
                                             Patch Test                            cleanliness level.
         Any fluid analysis should           A patch test is nothing more than
                                                                                   The margin of error for both of these
         always include a particle           a visual analysis of a fluid sample. It
                                                                                   methods is relatively high due to the
                                             usually involves taking a fluid sample
         count and corresponding                                                   human factor.
                                             and passing it through a fine media
         ISO code.                           “patch”. The patch is then analyzed
                                             under a microscope for both color and