EVP SERIES 2-WAY PROPORTIONAL CONTROL VALVES





                                                                                   Typical Performance
                                                                       25
                                                                           54 Ohmg Coil
                                                                           0.025 Orifice
                                                                           100 psig
                                                                       20  23˚C
                                                                       Flow (Liters/Minute)  15





                                                      RoHS             10
             Based on Clippard’s original spider design from 1973, the EVP’s ar-  5
             mature is the heart of the valve which provides precise flow control.


                                       Medium: Clean, dry air or inert gases             0
                                                                         0  .02  .04  .06  .08  .10  .12  .14  .16  .18  .20
                                       Power Consumption: 1.9 watts at 73°F,          Input Current (amps)
                                        2.3 watts max                                                 Operating Pressure
                                       Temperature Range: 32 to 120°F   The EVP Proportional Valve can be calibrated for pres-
                                                                      sures less than the Maximum Pressure shown above.
                       outlet          Ports: #10-32 Female (in-line), #10-32
           inlet                                                      Lower pressures may be substituted in increments of 5
                                        Male Stud (manifold).
                                        (see page 191 for manifold options)  psig, and will be used for calibration. For pressures less
                                 outlet                               than 5 psig, please consult Clippard Instrument Labora-
                            inlet
                                       Seal Material: Nitrile; FKM and EPDM.  tory, Inc.
              In-Line Mount    Manifold Mount  Others available.
                                                                      Note: Voltage, Orifice and Pressure are determined by the Part
                                       Maximum Hysteresis: 10% of full   Number configured on the following page.
                                         current

                                                     Maximum Flow vs. Operating Pressure
                  25.0
                 (53.0)
                                                                                                             0.025”
                                                                                                             Orifice

                  20.0                      0.060”                     0.040”
               Flow (±10%) at Maximum Current, slpm (scfh)  (31.8)  Orifice                                  0.013”
                 (42.4)
                                                                       Orifice

                  15.0




                  10.0
                 (21.2)

                                                                                                             Orifice
                  5.0
                 (10.6)
                                                                                                             0.009”
                                                                                                             Orifice


                  0.0
                      0        10       20       30        40        50       60       70       80       90       100
                                                                Inlet Pressure (psig)
                  To determine the correct orifice required, locate the colored line immediately above the flow/pressure intersection
                  Example: 9 slpm required at 45 psig inlet. This example leads to a “-2545” valve (0.025” nozzle, 45 psig).


         205                                             Clippard Instrument Laboratory, Inc. 877-245-6247 www.clippard.com