Page 31 - Clippard - Electronic Valves
P. 31
EVP SERIES 2-WAY PROPORTIONAL CONTROL VALVES
Typical Performance
25
54 Ohmg Coil
0.025 Orifice
100 psig
20 23˚C
Flow (Liters/Minute) 15
RoHS 10
Based on Clippard’s original spider design from 1973, the EVP’s ar- 5
mature is the heart of the valve which provides precise flow control.
Medium: Clean, dry air or inert gases 0
0 .02 .04 .06 .08 .10 .12 .14 .16 .18 .20
Power Consumption: 1.9 watts at 73°F, Input Current (amps)
2.3 watts max Operating Pressure
Temperature Range: 32 to 120°F The EVP Proportional Valve can be calibrated for pres-
sures less than the Maximum Pressure shown above.
outlet Ports: #10-32 Female (in-line), #10-32
inlet Lower pressures may be substituted in increments of 5
Male Stud (manifold).
(see page 191 for manifold options) psig, and will be used for calibration. For pressures less
outlet than 5 psig, please consult Clippard Instrument Labora-
inlet
Seal Material: Nitrile; FKM and EPDM. tory, Inc.
In-Line Mount Manifold Mount Others available.
Note: Voltage, Orifice and Pressure are determined by the Part
Maximum Hysteresis: 10% of full Number configured on the following page.
current
Maximum Flow vs. Operating Pressure
25.0
(53.0)
0.025”
Orifice
20.0 0.060” 0.040”
Flow (±10%) at Maximum Current, slpm (scfh) (31.8) Orifice 0.013”
(42.4)
Orifice
15.0
10.0
(21.2)
Orifice
5.0
(10.6)
0.009”
Orifice
0.0
0 10 20 30 40 50 60 70 80 90 100
Inlet Pressure (psig)
To determine the correct orifice required, locate the colored line immediately above the flow/pressure intersection
Example: 9 slpm required at 45 psig inlet. This example leads to a “-2545” valve (0.025” nozzle, 45 psig).
205 Clippard Instrument Laboratory, Inc. 877-245-6247 www.clippard.com