2-WAY PROPORTIONAL VALVES, IN-LINE &
MANIFOLD MOUNT
1.560
(39.6)
OUT 10 VDC 20 VDC
IN
0.156 5 VDC Base Part No.
In-Line Mount Manifold Mount
Voltage In-Line Mount Manifold Mount Operating Range & Orifice
#6-32 thd. -7/32 deep • EC-P-05-* EC-PM-05-*
mounting holes
#10-32
thd. inlet #10-32 In selecting your valve, you
thd. outlet
may have many variables to
• EC-P-10-* EC-PM-10-* choose from. Each variable
0.500
will affect others and this is a
0.025” Pin smple guide to provide
0.875 1.388 Connector • EC-P-20-* EC-PM-20-* assistance. To select the best
valve for your application,
focus on these three: Control
#6-32 thd. - 7/32 deep • ET-P-05-* ET-PM-05-* Signal, Valve Orifice and
mounting holes
Operating Pressure.
#10-32
thd. outlet
• ET-P-10-* ET-PM-10-* For Example
0.513
Spade Terminals • ET-P-20-* ET-PM-20-* EV -PM-20 - 25 85
Orifice Diameter
• EV-P-05-* EV-PM-05-*
#6-32 thd. - 7/32 deep Operating Pressure
mounting holes
#10-32 thd.
outlet
• EV-P-10-* EV-PM-10-*
Wire
Leads Side
(Radial) • EV-P-20-* EV-PM-20-*
* Consult factory for availability of non-standard voltages and other options
Although voltage in an important issue, the current is somewhat more The EVP Valve can be calibrated for pressures less than the maximum
Important: It is very important to specify and use a calibrated valve shown above. Lower pressures may be substituted in increments of
that matches your application. Be sure to use a valve set to your op- 5 psig, and will be used for calibration. The pressures shown above
erating pressure to assure you have an overall good performing valve are standard options. For pressures less than 5 psig or greater than
for your exact requirements. the Maximum Pressure listed, please consult factory.
important to this valve. It works by having a change in current vary
the magnetic field, which varies the travel or distance the valve is Standard Valve Orifices & Flow
opening. Max Flow Part No. Max. Pressure
Orifice (l/min)* Code (psig)
Control Signal
0.009” 2.7 ±10% 09 100 psig
Nominal Voltage Input Current Coil Resistance Max. Voltage 0.013” 6.7 ±10% 13 100 psig
Range @ 73°F (VDC) Range (amps) @ 73°F (ohms) Required (VDC) 0.025” 22.0 ±10% 25 100 psig
0 to 5 0 to 0.370 13.5 6.2 0.040” 18.7 ±10% 40 50 psig
0 to 10 0 to 0.185 54 12.4 0.060” 14.0 ±10% 60 25 psig
0 to 20 0 to 0.092 218 24.8 * Measured at Maximum Pressure
Do not exceed input current range.
❑ Base Part No. plus ❑ ❑ - ❑
Ports: Orifice: Options:
Blank - Nitrile seals (standard)
Blank #10-32 09 - 0.009” dia. Maximum Pressure
13 - 0.013” dia. (specify Operating E - EPDM seals
25 - 0.025” dia. Pressure): V - FKM seals
40*- 0.040” dia.
See Page 205 for flow 60*- 0.060” dia. - 5 to 99 psig
chart/selection AO - 100 psig View additional valve
* See Max. Pressure above RoHS selection tips