Page 97 - Schroeder - Fuel Filtration
P. 97

Single Tower Eco Pure Purification Systems                                      EWU
                                                  2
                                                       Features and Benefits                                         ICF
                                                          ■ Rugged stainless steel construction
                                                          ■ Easily retro-fitted to your existing production line    BDF
                                                          ■ Designed for easy change outs
                                                          ■ Single-pass process                                    BDFA
                                                          ■ Dry/waterless process
                                                          ■ Replacing Eco Pure media is fast and simple             BDA
                                                                   2
                                                                                                                    QCF
                                                       Application Introduction:
                                                                                                                    BDS
                                                       The single tower Eco Purepurification system
                                                                       2
                                                       combines the performance of the second                      BDS2
                                                       generation dry wash media, Eco Pure, the filtration
                                                                               2
                                                                                             ®
                                                       performance of Schroeder Industries’ Excellement
                                                       media and 65 years of US manufactured quality.              BDS3
                                                       Systems include controls, safety considerations,
                                                       Online quality control options and operator                 BDS4
                                                       feedback for ease of use.
              Single 70 kg Tower w/ Performance Filter                                                             LVH-F
                                        Flow Rating: 2 - 2.6 gpm (7.5 - 10 L/min)                   Specifications
                                                                                                                  LVH-C
                       Daily Production Volumes (24 hrs): 2,853 - 3,804 gals (10,800 - 14,400 L)
                               Final Filtration Method: Excellement  Beta1000 Media
                                                          ®
                                                                                                                   BDFC
                               Changeover Frequency: ± 7,925 gals (± 30,000 L)
                          Estimated Annual Production: 1,300,000 gal (4,921,035 L)
                                                                                                                    BDC
              How to Build a Valid Model Number for a Schroeder EWU:                                Filter       HDP-BC
                BOX 1  BOX 2  BOX 3  BOX 4  BOX 5  BOX 6  BOX 7
               EWU –       –     –     –     –     –                                                Model        HDP-HT
              Example: NOTE: One option per box                                                     Number
                BOX 1  BOX 2  BOX 3  BOX 4  BOX 5  BOX 6  BOX 7                                     Selection
               EWU – 1 – 50K – 2W – 1 – WQ – 0           = EWU150K2W1WQ0                                            EPM
                                                                                                                   EPTT
                 BOX 1         BOX 2               BOX 3                BOX 4
               Filter Series  No. of Towers  Treatment Tower Capacity  Filtration Stages
                                                                                                                   EWU
                                                                                                                   EWU
                 EWU            1             50K = 110 lbs. (50 kg)     2W
                      BOX 5                   BOX 6                   BOX 7                                         BCC
                   Power Options            Connector              Quality Control
               1 = 110V 60Hz          WQ =  Hoses w/ Quick Disconnect  0 = Blank Port
               2 = 220V 60Hz 1 phase  16M =  1" NPT              1 = TCM Particle Monitor
               3 = 460V/120V 3 phase  16V =  1" Cam Lock         2 = TWS Water Sensor
               4 = 575V              16Q =  1" Quick Disconnects  3 = TCM & TWS
               5 = Air Diaphragm
               6 =  110V 50Hz
              NOTES:
                   Other sizes available upon request
                   We can design, build and commission a purification system to suit your operation. For more
                   information please contact us to discuss your requirements.
                   Box 5. For 50 Hz applications contact the factory





                                                            SCHROEDER INDUSTRIES | FUEL FILTRATION     97
   92   93   94   95   96   97   98   99   100   101   102