            Performance Data












































            Combined First and Second stage torque cannot exceed:
              800 in. lb. Total continuous duty
              950 in. lb. Total intermittent duty

            Second stage torque cannot exceed 260 in. lb.

            Example:
            H39 @ 2500 PSI = 190 in. lb. x 2.5/1000 PSI = 475 in. lb. torque
            D17 @ 2500 PSI =   81 in. lb. x 2.5/1000 PSI = 203 in. lb. torque
                                                       678 in. lb. total torque