Page 145 - Parker - Vacuum products
P. 145
Catalog 0802-E Pressure Sensors
Programming Features MPS-34 2-Color Panel Mount
Fine adjustment mode
Measure mode
SET + This function eliminates slight differences in the output
Press SET + button for more than 3 seconds. values and allows uniformity in the numbers displayed.
Displayed values of the pressure sensor can be
Mutually display calibrated to within ±5% for MPS-P34 and ±2.5% for
series MPS-V34.
Current measured value
Use or button to change the set value.
SET 1x Press SET when finished or make no button operation for ±5% R.D.
±2.5% R.D.
more than 3 seconds after changing the set value to exit.
0
Mutually display Displayed pressure value Applied Pressure
Adjusted value (Percent)
SET 1x Measure mode :Factory setting display value set
prior to shipment
(Note) :Display calibration range
MPS-34 : When display unit is in “MPa”, setting resolution is 0.001 MPa. C
MPS-34 : When display unit is in “kPa”, setting resolution is 0.1 kPa.
Technical
Error messages
Error name Display Description Solutions MPS-33
Turn off power and check the cause of overload
Excess load
current error oCP Output load current of 125 mA current or lower the current load under 125 mA,
then restart MPS-34
Residual pressure oUr During zero reset, ambient pressure is over ±3% F.S. Change input pressure to ambient pressure and
error perform zero reset again
The applied pressure is excess the upper limit of
HHH
Applied pressure pressure setting Adjust the pressure within applied pressure range SCP01
error The applied pressure is excess the lower limit of
LLL
pressure setting
Er4 Internal data error SCPSD
Er6 Internal system error Turn power off and then restart. If error condition
System Error
Er7 Internal data error remains, please return to factory for inspection
Accessories, Symbols, Glossary
Er8 Internal system error
C15 Parker Hannifin Corporation