Page 143 - Parker - Vacuum products
P. 143
Catalog 0802-E Pressure Sensors
Programming Features MPS-34 2-Color Panel Mount
Initial setting mode
SET 1. Unit setting
Press SET button for more than 3 seconds. SET 1x 5. Response time setting
kPa kgf/cm 2 bar psi inHg(*1) mmHg(*1) 2.5ms 24ms 250ms 500ms 1000ms 1500ms
Note: *1: Only for MPS-V34 Use the or button to set response time.
Use the or button to set desired pressure unit. SET 1x 6. Auto preset setting
SET 1x 2. Display color setting
Manual Auto
ON: ON: ON / OFF: ON / OFF: Use the or button to select auto / manual.
GREEN RED GREEN RED
Use the or button to set display color. SET 1x 7. Measure mode
C
SET 1x 3. Operating mode setting
Hysteresis Window Comparator
Mode Mode
Use the or button to set operating mode.
Technical
SET 1x 4. Output type setting
MPS-33
NO Mode NC Mode
Use the or button to set output type.
MPS-34
SCP01
Zero point setting / the max. & min. Key lock / unlock mode
display mode
SET Key lock / unlock mode
Zero setting: Press SET button for less than 5 seconds.
• press the button at the same time until the SCPSD
“00” is shown. Release the button to end zero Use the or button to
Lock
setting. Unlock Mode select Lock / Unlock Mode.
Mode
The max. value display mode: Measure mode Accessories, Symbols,
• Press button 2 seconds to enter the max. SET 1x Glossary
value mode, pressure sensor will detect the max. • Key lock mode can prevent operation mistakes.
value and keep max. value displayed.
• Press button 2 seconds to return to measure
mode display.
The min. value display mode:
• Press button 2 seconds to enter the min.
value mode, pressure sensor will detect the min.
value and keep min. value displayed.
• Press button 2 seconds to return to measure
mode display.