Page 138 - Parker - Vacuum products
P. 138

Catalog 0802-E                                      Pressure Sensors
            Programming Features                                MPS-33 1-Color Panel Mount

            Initial setting mode


                SET   1. Unit setting
                      Press SET button for more than 3 seconds.
                                                                         SET  1x  4. Response time setting
                     Model: MPS-P33, MPS-R33
                                                                               2.5ms  24ms  192ms  768ms
                      MpA   kgf/cm 2  bar  psi
                                                                               Use the   or    button to select response time.
                     Model: MPS-V33
                                                                         SET  1x  5. Pressure value setting: auto / manual
                      MpA   kgf/cm 2  bar  psi  inHg  mmHg   mmH 2 O
                      Use the   or    button to set desired                 Manual    Auto
                      pressure unit.                                           Setting  Setting
                                                                               Mode     Mode
                                                                               Use the   or    button to select auto / manual.
                SET  1x  2. Out 1 mode setting
                                                                         SET  1x  Measure mode
                     NO Mode
                               NC Mode
     C               Use the   or    button to set OUT1 mode.
                     Output Type:
                     NO: Normal open mode
                     NC: Normal closed mode

                SET  1x  3. Out 2 mode setting

                     NO Mode   NC Mode
       Technical
                     Use the   or    button to set OUT1 mode.
                     Output Type:
                     NO: Normal open mode
                     NC: Normal closed mode
       MPS-33



       MPS-34
                                                                Dustproof protector

       SCP01
            Zero point setting / the max. & min.                Note: Required for IP65 rating protection and is included with
                                                                sensor.
            display mode
            Zero setting:
       SCPSD
            •  press the button at the same time until the
              “00” is shown. Release the button to end zero   OUT1  OUT2
              setting.
                                                       SET
                                                                                          Dustproof
            The max. value display mode:                                                  Protector
            •  Press  button 2 seconds to enter the max.
   Glossary
     Symbols,
              value mode, pressure sensor will detect the
       Accessories,
              max. value and keep max. value displayed.         Key lock / unlock mode
                                                     OUT1  OUT2
            •  Press  button 2 seconds to return to measure   SET   SET   Key lock / unlock mode
              mode display.                                                Press  SET  button for less than 5 seconds.
            The min. value display mode:
            •  Press  button 2 seconds to enter the min.                                 Use the    or    button to
              value mode, pressure sensor will detect the min.   OUT1  OUT2  Unlock  Mode  select Lock / Unlock Mode.
                                                                                     Lock
                                                                           Mode
              value and keep min. value displayed.     SET
            •  Press  button 2 seconds to return to measure         SET 1x  Measure mode
              mode display.                                                • Key lock mode can prevent operation mistakes.