Page 138 - Parker - Vacuum products
P. 138
Catalog 0802-E Pressure Sensors
Programming Features MPS-33 1-Color Panel Mount
Initial setting mode
SET 1. Unit setting
Press SET button for more than 3 seconds.
SET 1x 4. Response time setting
Model: MPS-P33, MPS-R33
2.5ms 24ms 192ms 768ms
MpA kgf/cm 2 bar psi
Use the or button to select response time.
Model: MPS-V33
SET 1x 5. Pressure value setting: auto / manual
MpA kgf/cm 2 bar psi inHg mmHg mmH 2 O
Use the or button to set desired Manual Auto
pressure unit. Setting Setting
Mode Mode
Use the or button to select auto / manual.
SET 1x 2. Out 1 mode setting
SET 1x Measure mode
NO Mode
NC Mode
C Use the or button to set OUT1 mode.
Output Type:
NO: Normal open mode
NC: Normal closed mode
SET 1x 3. Out 2 mode setting
NO Mode NC Mode
Technical
Use the or button to set OUT1 mode.
Output Type:
NO: Normal open mode
NC: Normal closed mode
MPS-33
MPS-34
Dustproof protector
SCP01
Zero point setting / the max. & min. Note: Required for IP65 rating protection and is included with
sensor.
display mode
Zero setting:
SCPSD
• press the button at the same time until the
“00” is shown. Release the button to end zero OUT1 OUT2
setting.
SET
Dustproof
The max. value display mode: Protector
• Press button 2 seconds to enter the max.
Glossary
Symbols,
value mode, pressure sensor will detect the
Accessories,
max. value and keep max. value displayed. Key lock / unlock mode
OUT1 OUT2
• Press button 2 seconds to return to measure SET SET Key lock / unlock mode
mode display. Press SET button for less than 5 seconds.
The min. value display mode:
• Press button 2 seconds to enter the min. Use the or button to
value mode, pressure sensor will detect the min. OUT1 OUT2 Unlock Mode select Lock / Unlock Mode.
Lock
Mode
value and keep min. value displayed. SET
• Press button 2 seconds to return to measure SET 1x Measure mode
mode display. • Key lock mode can prevent operation mistakes.
C8 Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics