Page 157 - Wagp_InterfaceElectronic_Volume4_2015_US.pdf
P. 157

Rail-Mounted Terminal Blocks with Optocoupler                                                           2

           with an extended input voltage and operating temperature range,  for railway applications
                                                                                                                    155

           Rail-mounted terminal blocks with optocouplers





                                                                                                                    2

           Description           Nominal input   Input voltage range   Max. switching capacity  Ambient operating   Item No.  Pack.
                                 voltage (V N )  (high level)                      temperature at V N          Unit
           Optocoupler, 2-wire output  5 V DC  2 ... 6.25 VDC   3 V ... 30 V DC / 50  mA  -40 °C ... +70 °C  859-795  1
           Optocoupler, 2-wire output  5 V DC  2 ... 6.25 VDC   3 V ... 60 V DC / 50  mA  -40 °C ... +70 °C  859-793  1
           Optocoupler, 2-wire output  12 VDC  8.4–15 VDC       9 V … 60 VDC / 50  mA  -40 °C ... +70 °C  859-798  1
           Optocoupler, 2-wire output  24 V DC  18 ... 30 VDC   3 V ... 30 V DC / 50  mA  -40 °C ... +70 °C  859-796  1
           Optocoupler, 2-wire output  24 V DC  16 ... 30 VDC   7 V ... 60 V DC / 50  mA  -40 °C ... +70 °C  859-791  1
           Optocoupler, 2-wire output  24 V DC  16 V ... 30 V DC  9 V ... 60 V DC / 50  mA  -40 °C ... +70 °C  859-794  1


           For additional technical data see: www.wago.com