Page 60 - Schroeder - Accessories
P. 60
Pressure Transmitter
Sensor How to Build a Valid Model Number for a Schroeder HDA41:
Model BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8
Number HDA41 – – – – – –
Selection Example: NOTE: One option per box
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8
HDA41 – 1 – 4 – A – 01.0 – 000 – F – 1 = HDA4114A01.0000F1
BOX 1 BOX 2 BOX 3 BOX 4
Model
Number Mechanical Connection Electrical Connection Signal
HDA41 1 = G1/2 B DIN-EN 837 (Male) 4 = Male, 4 pole Binder Series 714 A = 4..20 mA, 2
conductor
M18 (connector not supplied)
4 = G1/4 A DIN 3852 (Male)
5 = Male, 3 pole + PE, EN175301- B = 0..10 V, 3
803 (DIN 43650) (connector conductor
supplied)
6 = Male, M12x1, 4 pole
(connector not supplied)
BOX 5 BOX 6 BOX 7 BOX 8
Pressure Modification Seal Material Material of Connection
Range Number (in contact with fluid) (in contact with fluid)
01.0 bar 000 = Standard F = FPM Seal (e.g.:for hydraulic oils) 1 = Stainless Steel
(14.5 psi) E = EPDM Seal (e.g.: for refrigerants)
02.5 bar
(36.2 psi)
Sensor How to Build a Valid Model Number for a Schroeder HDA47:
Model BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6
Number HDA47 – – – – –
Selection Example: NOTE: One option per box
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6
HDA47 – 2 – 4 – A – 006 – 000 = HDA4724A006000
BOX 1 BOX 2 BOX 3 BOX 4
Model
Number Mechanical Connection Electrical Connection Signal
2 = G1/2 A DIN 3852 (only for 4 = Male, 4 pole Binder Series 714 A = 4..20 mA, 2
HDA47 “1000 bar press. range) M18 (connector not supplied) conductor
4 = G1/4 A DIN 3852 (Male) 5 = Male, 3 pole + PE, EN175301- B = 0..10 V, 3
803 (DIN 43650) (connector conductor
supplied)
6 = Male, M12x1, 4 pole
(connector not supplied)
BOX 5 BOX 6
Modification
Pressure Range
Number
006 bar (87.02 psi) 000 = Standard
016 bar (232.06 psi)
060 bar (870.23 psi)
100 bar (1450.38 psi)
250 bar (3625.94 psi)
NOTE:
400 bar (5801.51 psi)
BOX 5: Only in conjunction 600 bar (8702.26 psi)
with mechanical 1000 bar (14503.77 psi)
connection type “2’.
58 SCHROEDER INDUSTRIES