                      Sensor     How to Build a Valid Model Number for a Schroeder HDA41:
                       Model        BOX 1   BOX 2  BOX 3  BOX 4  BOX 5  BOX 6  BOX 7  BOX 8
                     Number       HDA41 –       –      –     –      –     –
                    Selection    Example: NOTE: One option per box
                                    BOX 1   BOX 2  BOX 3  BOX 4  BOX 5  BOX 6  BOX 7  BOX 8
                                  HDA41 –    1  –  4   – A – 01.0 – 000 –     F  –  1    = HDA4114A01.0000F1


                                   BOX 1             BOX 2                      BOX 3                  BOX 4
                                   Model
                                   Number       Mechanical Connection       Electrical Connection      Signal
                                  HDA41      1 = G1/2 B DIN-EN 837 (Male)  4 =  Male, 4 pole Binder Series 714   A = 4..20 mA, 2
                                                                                                      conductor
                                                                          M18 (connector not supplied)
                                             4 = G1/4 A DIN 3852 (Male)
                                                                       5 = Male, 3 pole + PE, EN175301-  B = 0..10 V, 3
                                                                          803 (DIN 43650) (connector   conductor
                                                                          supplied)
                                                                       6 = Male, M12x1, 4 pole
                                                                          (connector not supplied)
                                   BOX 5        BOX 6                 BOX 7                       BOX 8
                                   Pressure   Modification          Seal Material           Material of Connection
                                   Range       Number            (in contact with fluid)     (in contact with fluid)
                                  01.0 bar   000 = Standard  F =  FPM Seal (e.g.:for hydraulic oils)  1 = Stainless Steel
                                  (14.5 psi)                E = EPDM Seal (e.g.: for refrigerants)
                                  02.5 bar
                                  (36.2 psi)







                      Sensor     How to Build a Valid Model Number for a Schroeder HDA47:
                       Model        BOX 1   BOX 2  BOX 3  BOX 4  BOX 5  BOX 6
                     Number       HDA47 –       –      –     –      –
                    Selection    Example: NOTE: One option per box
                                    BOX 1   BOX 2  BOX 3  BOX 4  BOX 5  BOX 6
                                  HDA47 –    2  –  4   – A – 006 – 000 = HDA4724A006000


                                   BOX 1             BOX 2                      BOX 3                  BOX 4
                                   Model
                                   Number       Mechanical Connection       Electrical Connection      Signal
                                             2 = G1/2 A DIN 3852 (only for   4 =  Male, 4 pole Binder Series 714   A = 4..20 mA, 2
                                  HDA47         “1000 bar press. range)   M18 (connector not supplied)  conductor
                                             4 = G1/4 A DIN 3852 (Male)  5 = Male, 3 pole + PE, EN175301-  B = 0..10 V, 3
                                                                          803 (DIN 43650) (connector   conductor
                                                                          supplied)
                                                                       6 = Male, M12x1, 4 pole
                                                                          (connector not supplied)


                                        BOX 5            BOX 6
                                                      Modification
                                     Pressure Range
                                                        Number
                                   006 bar (87.02 psi)  000 = Standard
                                   016 bar (232.06 psi)
                                   060 bar (870.23 psi)
                                  100 bar (1450.38 psi)
                                  250 bar (3625.94 psi)
          NOTE:
                                  400 bar (5801.51 psi)
          BOX 5: Only in conjunction    600 bar (8702.26 psi)
               with mechanical    1000 bar (14503.77 psi)
               connection type “2’.
                              58  SCHROEDER INDUSTRIES
   55   56   57   58   59   60   61   62   63   64   65