Page 61 - Schroeder - Accessories
P. 61

Pressure Transmitter with HSI-Sensor Recognition



                                                                                                               Air Breathers
            The pressure transmitter HDA 4748-H with HSI sensor recognition has been specially developed for use in   HDA-4748-H  Air Breathers
            conjunction with measuring instruments HMG 3000 or HMG 3010. For data transmission, the HDA 4748-H has
            an HSI interface (Sensor Interface). The HSI sensors are automatically recognized via the HSI interface by the   Suction
                                                                                                                   Suction
            above-mentioned measuring instruments and all necessary basic device settings are taken from each sensor.   Separators
                                                                                                                Separators
                                                                                                                     and
            Like all pressure transmitters of the HDA 4700 series, the HDA 4748-H also has a very accurate and robust   and
                                                                                                                  Strainers
            sensor cell with a thin-film strain gauge on a stainless steel membrane. It combines excellent technical   Strainers
            specifications with a very compact design.
                                                                                                                  Oil Sight
                                                                                                                  Oil Sight
            Features and Benefits                                                                                  Glasses
                                                                                                                   Glasses
                ■ Fully automatic recognition by, and voltage     ■ Highly robust sensor cell
               supply from measuring instruments HMG3000     ■ Very small temperature error
               or HMG3010                                ■  Excellent EMC characteristics                        Electronic
                ■ Automatic transfer of measuring range,                                                          Sensors
               measured value and measurement unit       ■ Very compact design
                ■ Accuracy ≤ ± 0.25% FS type             ■ Excellent long term stability
                                                                                                                Fluid Level
                                                                                                                 Indicators

              Input Data                                                                       Specifications
                                    Measuring Ranges 1 : -14.5 to 130.5 psi (-1 to 9 bar); 232 psi (16 bar); 870 psi (60
                                                   bar); 1450 psi (100 bar); 3626 psi (250 bar); 5801 psi (400 bar);
                                                   8702 psi (600 bar); 14503 psi (1000 bar)
                                     Overload Pressures: 290 psi (20 bar); 464 psi (32 bar); 1740 psi (120 bar); 2900 psi
                                                   (200 bar); 7252 psi (500 bar); 11603 psi (800 bar); 14503 psi
                                                   (1000 bar); 23206 psi (1600 bar)
                                       Burst Pressures: 1450 psi (100 bar); 2900 psi (200 bar); 4351 psi (300 bar);
                                                   7252 psi (500 bar); 14503 psi (1000 bar); 29007 psi (2000 bar);
                                                   43511 psi (3000 bar)
                                 Mechanical Connection 1 : G 1/4 A DIN 3852 ; G 1/2 A DIN 3852
                                         Torque Value: 20 Nm (G1/4); 45 Nm (G1/2)
                              Parts in Contact w/ Medium: Mech. Connection: Stainless Steel
                                                   Seal: FPM
             Output Data
                                        Output Signal: HSI (Sensor Interface) Automatic Sensor Recognition
                         Accuracy to DIN 16086, Max Setting: ≤ ± 0.25% FS typ.
                                                   ≤ ± 0.5% FS max.
                            Accuracy at min. Setting B.F.S.L.: ≤ ± 0.15% FS typ.
                                                   ≤ ± 0.25% FS max.
                      Temperature Compensation Zero Point: ≤ ± 0.008% FS / °C typ.
                                                   ≤ ± 0.015% FS / °C max.
                     Temperature Compensation Over Range: ≤ ± 0.008% FS / °C typ.
                                                   ≤ ± 0.015% FS / °C max.
                    Non-linearity at Max. Setting to DIN 16086: ≤ ± 0.3% FS max.
                                           Hysteresis: ≤ ± 0.1% FS max.
                                         Repeatability: ≤ ± 0.05% FS
                                            Rise Time: ≤  0.5 ms
                                       Long-term Drift: ≤ ± 0.1% FS typ. / year
             Environmental Conditions
                          Compensated Temperature Range: -13°F to 185°F (-25°C to 85 °C)
                            Operating Temperature Range 2 : -40°F to 185°F / -13°F to 185°F (-40°C to 85°C / -25°C to 85
                                                   °C)
                              Storage Temperature Range: -40°F to 212°F (-40°C to 100 °C)      Notes:   Reverse polarity protection
                                Fluid Temperature Range 2 : -40°F to 212°F / -13°F to 212°F (-40°C to 100 °C / -25°C to   of the supply voltage,
                                                   100°C)                                           excess voltage, override and
                                                                                                    short circuit protection are
                                                                                                    provided.
                                               Mark: EN 61000-6-1/2/3/4                             FS (Full Scale) = relative to
             Vibration resistance to  DIN EN 60068-2-6 at 10 .. 500                                 complete measuring range
                                                Hz: ≤ 20 g                                          B.F.S.L.= Best Fit Straight
                              Protection Class to IEC 60529: IP 67 (when an IP 67 connector is used)  Line
                                                                                                    1) 1000 bar only with
             Other Data                                                                             mechanical connection
                                        Voltage Supply: via measuring instruments HMG3000 or HMG3010  G 1/2 A DIN 3852
                                       Life Expectancy: > 10 million cycles 0 .. 100% FS            and vice versa
                                                                                                    2) -25 °C with FPM seal,
                                             Weight: 0.33 lbs (0.15 kg)                             -40 °C on request






                                                                       SCHROEDER INDUSTRIES   59
   56   57   58   59   60   61   62   63   64   65   66