Page 61 - Schroeder - Accessories
P. 61
Pressure Transmitter with HSI-Sensor Recognition
Air Breathers
The pressure transmitter HDA 4748-H with HSI sensor recognition has been specially developed for use in HDA-4748-H Air Breathers
conjunction with measuring instruments HMG 3000 or HMG 3010. For data transmission, the HDA 4748-H has
an HSI interface (Sensor Interface). The HSI sensors are automatically recognized via the HSI interface by the Suction
Suction
above-mentioned measuring instruments and all necessary basic device settings are taken from each sensor. Separators
Separators
and
Like all pressure transmitters of the HDA 4700 series, the HDA 4748-H also has a very accurate and robust and
Strainers
sensor cell with a thin-film strain gauge on a stainless steel membrane. It combines excellent technical Strainers
specifications with a very compact design.
Oil Sight
Oil Sight
Features and Benefits Glasses
Glasses
■ Fully automatic recognition by, and voltage ■ Highly robust sensor cell
supply from measuring instruments HMG3000 ■ Very small temperature error
or HMG3010 ■ Excellent EMC characteristics Electronic
■ Automatic transfer of measuring range, Sensors
measured value and measurement unit ■ Very compact design
■ Accuracy ≤ ± 0.25% FS type ■ Excellent long term stability
Fluid Level
Indicators
Input Data Specifications
Measuring Ranges 1 : -14.5 to 130.5 psi (-1 to 9 bar); 232 psi (16 bar); 870 psi (60
bar); 1450 psi (100 bar); 3626 psi (250 bar); 5801 psi (400 bar);
8702 psi (600 bar); 14503 psi (1000 bar)
Overload Pressures: 290 psi (20 bar); 464 psi (32 bar); 1740 psi (120 bar); 2900 psi
(200 bar); 7252 psi (500 bar); 11603 psi (800 bar); 14503 psi
(1000 bar); 23206 psi (1600 bar)
Burst Pressures: 1450 psi (100 bar); 2900 psi (200 bar); 4351 psi (300 bar);
7252 psi (500 bar); 14503 psi (1000 bar); 29007 psi (2000 bar);
43511 psi (3000 bar)
Mechanical Connection 1 : G 1/4 A DIN 3852 ; G 1/2 A DIN 3852
Torque Value: 20 Nm (G1/4); 45 Nm (G1/2)
Parts in Contact w/ Medium: Mech. Connection: Stainless Steel
Seal: FPM
Output Data
Output Signal: HSI (Sensor Interface) Automatic Sensor Recognition
Accuracy to DIN 16086, Max Setting: ≤ ± 0.25% FS typ.
≤ ± 0.5% FS max.
Accuracy at min. Setting B.F.S.L.: ≤ ± 0.15% FS typ.
≤ ± 0.25% FS max.
Temperature Compensation Zero Point: ≤ ± 0.008% FS / °C typ.
≤ ± 0.015% FS / °C max.
Temperature Compensation Over Range: ≤ ± 0.008% FS / °C typ.
≤ ± 0.015% FS / °C max.
Non-linearity at Max. Setting to DIN 16086: ≤ ± 0.3% FS max.
Hysteresis: ≤ ± 0.1% FS max.
Repeatability: ≤ ± 0.05% FS
Rise Time: ≤ 0.5 ms
Long-term Drift: ≤ ± 0.1% FS typ. / year
Environmental Conditions
Compensated Temperature Range: -13°F to 185°F (-25°C to 85 °C)
Operating Temperature Range 2 : -40°F to 185°F / -13°F to 185°F (-40°C to 85°C / -25°C to 85
°C)
Storage Temperature Range: -40°F to 212°F (-40°C to 100 °C) Notes: Reverse polarity protection
Fluid Temperature Range 2 : -40°F to 212°F / -13°F to 212°F (-40°C to 100 °C / -25°C to of the supply voltage,
100°C) excess voltage, override and
short circuit protection are
provided.
Mark: EN 61000-6-1/2/3/4 FS (Full Scale) = relative to
Vibration resistance to DIN EN 60068-2-6 at 10 .. 500 complete measuring range
Hz: ≤ 20 g B.F.S.L.= Best Fit Straight
Protection Class to IEC 60529: IP 67 (when an IP 67 connector is used) Line
1) 1000 bar only with
Other Data mechanical connection
Voltage Supply: via measuring instruments HMG3000 or HMG3010 G 1/2 A DIN 3852
Life Expectancy: > 10 million cycles 0 .. 100% FS and vice versa
2) -25 °C with FPM seal,
Weight: 0.33 lbs (0.15 kg) -40 °C on request
SCHROEDER INDUSTRIES 59