Page 47 - Schroeder - Process Filtration
P. 47
Backflushing High Pressure Filter RFH-1 RFH-1
How to Build a Valid Model Number for a RFH: Filter RF3-C
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11 BOX 12 BOX 13 BOX 14 BOX 15 BOX 16 Model
RFH 1
Number RF3-0
Selection
Example: NOTE: One option per box
RF3-1
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11 BOX 12 BOX 13 BOX 14 BOX 15 BOX 16
RFH 1 G 25 M 0 N 1 0 X RH 1 50 S N = RFH1G25M0N10X
RH150SN1
RF3-2
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 RF3-2.5
Filter Size Connection Type
Series (flow) Connection Size Material
RF3-3
RFH 1 = 105 gpm (400 L/min) S = Steck-O (staple 25 = 25mm M = Brass
lock) DN25
E = Stainless
G = 1 ISO female G Steel RF3-4
thread
M/E = Brass/
Stainless
Steel RF3-5
combination
RF3-6
BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11 RF3-7
Special Equipment Seal Control Type Supplemental Modification Element
Number
Details
Type
Material
0 = no special 1= Manual 0 = none X = Latest RH = Backflushing RF3-8
equipment N = NBR version high
1 = ATEX is always pressure
V = Viton certificate supplied element
(Ex: M2C RF5
Mining)
RF7
RF4-1
RF4-2
BOX 12 BOX 13 BOX 14 BOX 15 BOX 16
Element Size Filtration Rating Element Material Element Seal Special Order RFH-1
RFH-1
Slotted Tube: D = Wire Mesh SO = Customer
1 N = Buna N Requirements
50, 100, 200, S = Slotted Tube (standard) Note: SO will RFH-2
500 μm change to a
V = Viton
numeric sequence
Wire Mesh: following receipt of RFH-4
25, 40, 60 μm order
ATF
*Shaded selections are preferred order codes that designate shorter lead times.
SCHROEDER INDUSTRIES | PROCESS FILTRATION 47