Page 86 - Schroeder - Process Filtration
P. 86

CH12-CH24             Cartridge Housings and Elements


              150 psi                                           Model CH12240
                10 bar































                                            Models CH14240 - CH24240



            Dimensions                 Cartridge  A     B     C     D     E      J     K     M    N3   N4
                                                 inch  inch  inch  øinch  inch  øinch  øinch  inch  inch  inch
                                      Qty  Length  (mm)  (mm)  (mm)  (mm)  (mm)  (mm)  (mm)  (mm)
                             CH12240  12    40   27.56  13.78  68.03  12.01  19.69  0.55  16.14  6.02  ½  1
                                                 (700)  (350)  (1728)  (305)  (500)  (14)  (410)  (153)
                             CH14240  14    40   27.56  13.78  76.77  15.98  23.86  0.55  20.31  14.96  ½  1
                                                 (700)  (350)  (1950)  (406)  (606)  (14)  (516)  (380)
                             CH18240  18    40   27.56  13.78  76.77  15.98  23.86  0.55  20.31  14.96  ½  1
                                                 (700)  (350)  (1950)  (406)  (606)  (14)  (516)  (380)
                             CH20240  20    40   27.56  13.78  76.77  15.98  23.86  0.55  20.31  14.96  ½  1
                                                 (700)  (350)  (1950)  (406)  (606)  (14)  (516)  (380)
                             CH24240  24    40   27.56  13.78  76.97  19.13  27.01  0.55  23.46  15.16  ½  1
                                                 (700)  (350)  (1955)  (486)  (686)  (14)  (596)  (385)






         Specifications      Number of Elements per Housing:  12, 14, 18, 20, or 24, 2" Diameter

                                   Max. Working Pressure:  150 psi (10 bar)
                                       Max Temperature:  167ºF (75ºC)
                                       Housing Material:  Stainless Steel (304 or 316)

                             *Max flow rate is dependent on type of media, particle selection required, fluid viscosity and volume of contamination.












                         86        SCHROEDER INDUSTRIES | PROCESS FILTRATION
   81   82   83   84   85   86   87   88   89   90   91