Page 6 - Parker - hydraulic motors M5AS/M5ASF
P. 6

Catalogue HY29-0024/UK                              Hydraulic Motors, Fixed
                  Motor Selection                                   M5AS/M5ASF, Denison Vane Motors


                Motor performances required  1. Check if available power is greater than required power (0.85 estimated overall efficiency).
                Torque .......................  T   [Nm.]       55
                Speed .......................  n   [rpm]   1500
                                                                                       30 x 250
                                                  Q x p
                Pump available data         0,85 x                >    T x p x n  0.85 x                   >     55 x p x 1500
                Flow ..........................  Q [l/min]       30    600  30 x 1000      600       30 x 1000
                D Pressure ................  D p [bar]     250  10,6  >  8,7  kW
                                            2. Two ways of calculation : Calculate V from T required torque, or from Q available flow.
                                                                           i

                                            2a.                                   2b.
                                                20 x p x T   20 x p x 55             1000 x Q  1000 x 30
                                            V =                    =                      = 13,8 cm /rev  V =                   =                   = 20,0 cm /rev
                                                                          3
                                                                                                             3
                                             i         p         250               i        n      1500
                                            3a. Choose motor from Vi immediately greater  3b. Choose motor from Vi immediately smaller
                                                              3
                                            M5AS* 016 : V = 16,0 cm /rev          M5AS* 018 : V = 18,0 cm /rev
                                                                                                    3
                                                       i                                    i
                                            4a. Check theoretical motor pressure  4b. Check theoretical motor pressure with
                                                                                  T = 55 Nm
                                                                                                 20 x p x 55
                                                           20 x p x 55
                                                                                       20 x p x T
                                                 20 x p x T
                                            D p =                    =                       = 216 bar  D p =                    =                       = 192 bar
                                                       V i         16,0                      V i         18,0
                                            Torque loss at this pressure = 3,0 Nm  Torque loss at this pressure = 3,3 Nm
                                            (See page 9)                          (See page 9)
                                            Calculate real pressure               Calculate real pressure
                                                  20 x p x (T + Tl)   20 x p x 58       20 x p x (T + Tl)   20 x p x 58,3
                                            D p  =                            =                    = 228 bar  D p  =                           =                      = 204 bar
                                              eff.              V i        16,0     eff.              V i         18,0
                                            5a. Flow loss at this pressure : 3,5 l/min  5b. Flow loss at this pressure : 4 l/min
                                            (See page 9)                          (See page 9)
                                            Real flow used by the motor :         Real flow used by the motor :
                                            Q  = 30 - 3,5 = 26,5 l/min            Q  = 30 - 4 = 26,0 l/min
                                             eff.                                  eff.
                                            6a. Real speed of the motor  :        6b. Real speed of the motor:
                                                Q  x 1000  26,5 x 1000                Q  x 1000  26,0 x 1000
                                            n  =                   =                     = 1656 rpm  n  =                   =                    = 1444 rpm
                                                                                       eff.
                                                 eff.
                                             eff.        V i        16,0           eff.        V i.       18,0
                                            Real performances                     Real performances
                                            V        = 16,0 cm /rev               V       = 18,0 cm /rev
                                                        3
                                                                                             3
                                             i
                                                                                   i
                                            n         = 1656 rpm                  n        = 1444 rpm
                                             eff.
                                                                                   eff.
                                            T         = 55 Nm.                    M       = 55 Nm.
                                            D p    = 228 bar                      D p   = 204 bar
                                              eff.                                  eff.
                FlUID POWer FOrMUlaS
                                                              1
                Volumetric efficiency               total leakage x 1000                  Speed          [rpm]
                                            1 +
                                                                                                           3
                                                   speed x displacement                   Displacement   [cm /rev]
                                                                                          Pressure       [bar]
                                                                                          Flow rate      [l/min]
                Mechanical efficiency                   torque loss x 20 x p              Leakage        [l/min]
                                            1 -
                                                   D pressure x displacement              Torque         [Nm]
                                                                                          Torque loss    [Nm]
                Fluid motor speed                         rpm  1000 x flow rate x volumetric eff.
                                                         displacement
                Fluid motor torque                        N.m  D pressure x displacement x mech. eff.
                                                                  20 x p

                Fluid motor power                         kW  speed x displacement x D pressure x overall eff.             or  torque x speed x 20 x p
                                                                  600 000                            600 000


                                                                   6                       Parker Hannifin SAS
                                                                                           VPDE, Denison Vane Motors
                                                                                           Vierzon - France
   1   2   3   4   5   6   7   8   9   10   11