Page 6 - BuTech - Actuator Selection Guide
P. 6
8" AIR-TO-OPEN
Model ATO8
9.25" (234.9) DIA
H
Spring Compression
Valve Model H 1/8" 3/16" 1/4" 5/16" 3/8" 7/16" 1/2" 9/16" 5/8"
DHP2 15,000
MAWP
DHP4 8.50" 1034 bar
DHP6 (215.9) Required 50 PSI
DHP8 Air Pressure 3.5 bar
1,500 2,000 2,000 2,500 3,000 3,500 4,000 4,500 5,000
MAWP
DHP12 9.38" 103 bar 138 bar 138 bar 172 bar 207 bar 241 bar 276 bar 310 bar 345 bar
DHP16 (238.3) Required 54 PSI 55 PSI 60 PSI 61 PSI 62 PSI 63 PSI 64 PSI 65 PSI 66 PSI
Air Pressure 3.7 bar 3.8 bar 4.1 bar 4.2 bar 4.3 bar 4.3 bar 4.4 bar 4.5 bar 4.6 bar
9,500 12,000 14,500 15,000
MAWP
SFPV6 8.69" 655 bar 827 bar 1000 bar 1034 bar
SFPV8 (220.7) Required 50 PSI 51 PSI 52 PSI 56 PSI
Air Pressure 3.5 bar 3.5 bar 3.6 bar 3.9 bar
2,500 3,000 3,500 4,000 5,000 5,500 6,000 7,000 7,500
MAWP
FPV12 10.63" 172 bar 207 bar 241 bar 276 bar 345 bar 379 bar 414 bar 483 bar 517 bar
FPV16 (270.0) Required 53 PSI 55 PSI 57 PSI 60 PSI 59 PSI 62 PSI 64 PSI 64 PSI 66 PSI
Air Pressure 3.7 bar 3.8 bar 3.9 bar 4.1 bar 4.1 bar 4.3 bar 4.4 bar 4.4 bar 4.6 bar
15,000 19,000 20,000
MAWP
20UV4 8.12" 1034 bar 1310 bar 1379 bar
20UV6 (206.2) Required 50 PSI 51 PSI 55 PSI
Air Pressure 3.5 bar 3.5 bar 3.8 bar
9,500 12,000 14,500 17,000 19,500 20,000
MAWP
10.00" 655 bar 827 bar 1000 bar 1172 bar 1344 bar 1379 bar
20UV9
(254.0) Required 50 PSI 51 PSI 52 PSI 53 PSI 54 PSI 58 PSI
Air Pressure 3.5 bar 3.5 bar 3.6 bar 3.7 bar 3.7 bar 4.0 bar
4,000 5,000 6,000 7,000 8,000 9,500 10,500 11,500 12,500
MAWP
8.50" 276 bar 345 bar 414 bar 483 bar 552 bar 655 bar 724 bar 793 bar 862 bar
20V12
(215.9) Required 53 PSI 55 PSI 57 PSI 58 PSI 60 PSI 60 PSI 62 PSI 64 PSI 66 PSI
Air Pressure 3.7 bar 3.8 bar 3.9 bar 4.0 bar 4.1 bar 4.1 bar 4.3 bar 4.4 bar 4.6 bar
2,500 3,000 3,500 4,000 5,000 5,500 6,000 7,000 7,500
MAWP
10.50" 172 bar 207 bar 241 bar 276 bar 345 bar 379 bar 414 bar 483 bar 517 bar
20V16
(266.7) Required 53 PSI 55 PSI 57 PSI 60 PSI 59 PSI 62 PSI 64 PSI 64 PSI 66 PSI
Air Pressure 3.7 bar 3.8 bar 3.9 bar 4.1 bar 4.1 bar 4.3 bar 4.4 bar 4.4 bar 4.6 bar
4,000 5,000 6,000 7,000 8,000 9,500 10,500 11,500 12,500
MAWP
9.03" 276 bar 345 bar 414 bar 483 bar 552 bar 655 bar 724 bar 793 bar 862 bar
30V16
(229.4) Required 53 PSI 55 PSI 57 PSI 58 PSI 60 PSI 60 PSI 62 PSI 64 PSI 66 PSI
Air Pressure 3.7 bar 3.8 bar 3.9 bar 4.0 bar 4.1 bar 4.1 bar 4.3 bar 4.4 bar 4.6 bar
110,000 135,000 150,000
MAWP
9.19" 7583 bar 9307 bar 10341 bar
150V
(233.4) Required 50 PSI 51 PSI 54 PSI
Air Pressure 3.5 bar 3.5 bar 3.7 bar
All dimensions are for reference only and are subject to change without notice.
Dimensions in parentheses are millimeters (mm). AO-09
Page AO-6