Page 41 - Parker- Parker global air preparation system
P. 41
Catalog 0750-3 US P33 Series
Global Air Preparation System Standard Regulators
Specifications Flow Charts
3
Flow capacity* 1/2 110 dm /s (233 scfm) 1/2 Regulator
3/4 110 dm /s (233 scfm) Inlet Pressure - 10 bar (145 psig)
3
Operating temperature -25°C to 65.5°C (-13°F to 150°F) 140 10 9
Max. supply pressure 20 bar (300 psig) 120 8 8.0 bar
Adjusting range pressure 0-2 bar (30 psig) 100 7 6 116 psig
6.3 bar
0-4 bar (60 psig) Secondary Pressure - (psig) 80 Secondary Pressure - bar 5 91.4 psig
0-8 bar (125 psig) 60 4
0-17 bar (250 psig) 40 3 2
4.0 bar
2.5 bar
Port size BSPP / BSPT / NPT 1/2, 3/4 20 1 36.3 psig 58 psig
Gauge port (2 ea.) BSPP / BSPT / NPT 1/4 0 0 0 20 40 60 80 100 120 140
3
Weight 0.62 kg (1.37 lbs) Flow - dm /s
0 40 80 120 160 200 240 280
* Inlet pressure 10 bar (145 psig). Secondary pressure 6.3 bar (91.3 psig). Flow - (scfm)
Material Specifications 3/4 Regulator
Inlet Pressure - 10 bar (145 psig)
Body Aluminum 140 10
9
Adjustment knob Acetal 120 8
8.0 bar
Body cap ABS 100 7 116 psig
Bonnet 33% Glass-filled nylon Secondary Pressure - (psig) 80 Secondary Pressure - bar 6 5
6.3 bar
Diaphragm assembly Nitrile / Zinc 60 4 91.4 psig
Bonnet 33% Glass-filled nylon 40 3 2
4.0 bar
2.5 bar
Valve assembly Brass / Nitrile 20 1 36.3 psig 58 psig
Springs Main regulating valve Steel S.S. 0 0 0 20 40 60 80 100 120 140 160
3
Flow - dm /s
Seals Nitrile 0 40 80 120 160 200 240 280 300 340
Panel nut Acetal Flow - (scfm)
Dimensions mm (inches)
NOTE: 61 mm (2.40 in.) hole 108 Round
required for panel nut mounting. 4.27) Gauge Repair and Service Kits
73
(2.87) Regulator repair kit - relieving P33KA00RB
73 37
(2.87) (1.44) Regulator repair kit - non-relieving P33KA00RC
Panel mount nut - aluminum P33KA00MM
44
(1.73) Panel mount nut - plastic P33KA00MP
83.8
(3.30) Angle bracket (attaches via panel nut) P33KA00MR
T-bracket with body connector P32KA00MT
149
(5.87) T-bracket P32KA00MB
Body connector P32KA00CB
Gauges
50mm (2") Round 1/4" center back mount
! WARNING 0-30 psig / 0-2 bar K4520N14030
Product rupture can cause serious injury. 0-60 psig / 0-4 bar K4520N14060
Do not connect regulator to bottled gas. 0-160 psig / 0-11 bar K4520N14160
Do not exceed Maximum primary pressure rating.
0-300 psig / 0-20 bar K4520N14300
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob For best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
adjustment is designed to permit outlet pressures within their full range.
Pressure adjustment beyond this range is also possible because the knob
is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing
the pressure up to the desired setting.
41 Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/globalfrl