Page 73 - Parker- Parker global air preparation system
P. 73
Catalog 0750-3 US (Revised 12-04-14) P33T Series
Global Air Preparation System Redundant Safety Exhaust Valves
Technical Information Repair and Service Kits
Pilot Solenoids: According to VDE 0580 Description Part number
Enclosure rating: According to DIN 400 50 IP65 Black grill 1834C05-001
Connector socket: According to DIN 43650 Form A
Three solenoids, rated for continuous duty Body connector P32KA00CB
Standard voltages: 24VDC Cables
M12, 5-pin female to flying lead cable,
Power consumption (each solenoid): TPE; 2 m (6.6 ft) ...................................................RKC 4.5T-2/S1587
for primary and reset solenoids: 1.2 Watts on DC M12, 5-pin male to flying lead cable,
Enclosure rating: IP65, IEC 60529 TPE; 2 m (6.6 ft) ...................................................RSC 4.5T-2/S1587
Electrical connection: M12, 5-pin Port block kit
1/2 NPT .........................................................................P32KA94CP
Ambient temperature: 15°F to 122°F (-10°C to 50°C)
3/4 NPT .........................................................................P32KA96CP
Media temperature: 40°F to 175°F (4°C to 80°C) 1/2 BSPP ......................................................................P32KA14CP
Flow media: Compressed Air, Filtered to Minimum 40 Micron 3/4 BSPP ......................................................................P32KA16CP
1/2 BSPT .......................................................................P32KA24CP
Inlet pressure: 30 to 150 PSIG (2 to 10 bar) 3/4 BSPT .......................................................................P32KA26CP
Pressure switch rating (Status indicator): 5 Amps at 30 Volts DC. Pressure switch 1227A30-001
Monitoring: Dynamically, cyclically, internally during each Pressure transducer (Optional) 1232H30-001
actuating and de-actuating movement.
Monitoring function has memory and requires T-bracket w/ body connector P32KA00MT
an overt act to reset unit after lockout. T-bracket (Fits to body connector or port block) P32KA00MB
Mounting orientation: Vertically with pilot solenoids on top Silencer(s) 3/4" 5500A5013
Port threads: 3/4 NPT, 3/4 BSPP Solenoid (Main & reset) 1527B7916-001
Control reliable: Category 4 (Cat 4); performance Square flush mounting gauge kit, 0-160 psig K4511SCR160
Level e (PLe) in accordance with
Machine directive - EN ISO 13849-1
(Certification pending)
Valve Wiring
5-Pin “A” Code 5-Pin “A” Code 5-Pin “A” Code Female Connector
Female Connector Male Connector (Digital Pressure Transducer
(Feedback) (Control Signal) Wiring (optional))
5 GRAY 5 GRAY 5 Power Input
(Equip Ground) Reset
BROWN 1 2 WHITE WHITE 2 1 BROWN Input 1 2 Digital
(+24 Volts DC) (N.O. Status (Sol 2) (+24 Volts DC) Power + Output Signal
Contact)
BLACK 4 3 BLUE BLUE 3 4 BLACK Analog 4 3 Digital
(N.C. Status (Common) (Common) (Sol 1) Output Signal Output 2 Signal
Contact)
Dimensions mm (inches)
100%
(+) Increase Time 60%
Control Feedback Pressure + (-) Decrease Time
Transducer -
16.3 Signal 5 1 2 Start signal
(.64) (Optional) 0% 3 Switching time delay
Gradual pressure build up
Manual
Reset 4 Operating pressure p 2 (=p 1 )
LED
Status
SOL.1 SOL.2 RESET SOL STATUS Angle Mounting Bracket
Lights 19.1 (0.75)
273.8 Inlet Outlet
(10.78) 9.5
(0.375) 8.6 81.3 (3.2)
(0.34)
76.2 (3.0)
6.4 8X R
145.5 (0.25) R 0.13 0.063 76.2
(5.73) 46.2 90° (3.0)
Adjustable (1.82)
Soft Start
11.1 76.2 (3.0)
(0.44) 98.4 (3.875)
41.3 (1.63) 147.6 (5.81)
136.0 (5.35) Note: Mounting bracket and installation screws included
and required to install unit in the system.
73 Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/globalfrl