Page 87 - Parker- Parker global air preparation system
P. 87

Catalog 0750-3 US                                                            PPS1 Pressure Switch
            Global Air Preparation System                                                  Kits & Accessories

            Pressure Switch – PPS1                              Dimensions

                                                                                               Wire Configuration
                                                  3 (Normally Open)                             Pin 1 - Common (Black)
                                                                                     Top View DIN   Pin 2 - N.C. (Blue)

                                                                                       3       Pin 3 - N.O. (Red)
                                          1                          1.50                         1.20
                                        (Common)  2 (Normally Closed)  (38.1)          2  GND 1    (30.5) Ø
                                                                                   Pin Configuration  18” Leads
                                                                                    Pin 1 - Common (Black)
                                                                                    Pin 2 - N.C. (Blue)
                                                                                    Pin 3 - N.O. (Red)
                                                                      2.50  Max.
                                                                     (63.5)                 2.30  Max.
                                                                                            (58.4)
                                                                     1-1/8 Hex             1-1/8 Hex
                                                                    1/8-27 NPT            1/4-18 NPTF
            •  Long life elastomer diaphragm
            •  High quality snap action switch                  Definitions and Terminology
            •  Field adjustable                                 Repeatability — Accuracy is the maximum allowable set point
            •  Compact design                                   deviation of a single pressure or temperature switch under one
                                                                given set of environmental and operational conditions.
            •  Easily customized
                                                                Single Pole Double Throw (SPDT) Switching element —
            •  Quick delivery                                   A SPDT switching element has one normally open, one
            •  NEMA 4, 13                                       normally closed and one common terminal. Three terminals
                                                                mean that the switch can be wired with the circuit either
                                                                normally open (NO), or normally closed (NC), or both.
                                                                Dead Band — The dead band, sometimes referred to as
                                                                “differential” or “hysteresis”, is the change in pressure between
            Operation                                           actuation and deactuation set points.
            The pressure switch monitors the air pressure in your
            pneumatic system. When the pressure in your system either   Specifications
            drops below or exceeds the set point pressure, an electrical   Set point tolerance   ±1 PSI or 5% (.07 bar)
            output is given.
                                                                Temperature range         -40F° to 220F° (-40C° to 105C°)
                                                                Max. operating pressure (Ranges 1, 2, 3)   250 PSI (17.2 bar)
                                                                Max. operating pressure (Range 4)   2000 PSI (137.9 bar)
                                                                Deadband                       10 - 20% of set pressure
                                                                Current rating                        3A @ 125 VAC
                                                                                                2A @ 30 VDC (Resistive)
                                                                Circuit form                          SPDT Standard
                                                                Cycle life                                 1 Million

                                                                Material Specifications
                                                                Adjustment knob                    Anodized aluminum
                                                                Body                                        Brass
                                                                Diaphragm                                   Nitrile
            Options:

                                       PPS1  -  1       C     3  -  R            HM


                                        Thread                        Set Point      Electrical
                                   1/4" NPT male  1                   Direction     Connection
                                   1/8" NPT male  2                  R  Rising    HM DIN 9.4mm
                                   1/4" BSPP male  17            Range*           WL Wire leads 18"
                                   1/8" BSPP male  18
                                                              1  3-10 PSI   * Factory setting for calibration purposes
                                                              2  6-30 PSI     Range 1 = 6 PSI
                                                   Circuit    3  20-120 PSI    Range 2 = 18 PSI
                                                 SPDT   C     4  100-400 PSI †    Range 3 = 70 PSI
             Note: Switch is field adjustable.               †  Only available in 1/4" NPT    Range 4 = 250 PSI


                                                             87                        Parker Hannifin Corporation
                                                                                       Pneumatic Division
                                                                                       Richland, Michigan
                                                                                       www.parker.com/globalfrl
   82   83   84   85   86   87   88   89   90   91   92