Page 89 - Parker - Process filtration
P. 89

®
                                      ™
          Fulfl o  TruBind  300 Filter Cartridge
          SPECIFICATIONS
          Materials of Construction           Recommended Vessels:                Performance
          Absorbent: Proprietary modifi ed polymer  All standard Fulfl o vessels designed for   TruBind absorbent cartridge effi ciency
          Support Construction: 100% polyolefi n  2-1/2 in OD cartridges.          depends upon the residence time of the
          Seal Material: Gasket (Polyethylene Foam);                              fl uid within the cartridge, which is a function
                                              Technology
          222 O-Ring (Buna-N)                                                     of the volumetric fl ow rate.
                                              Unlike competitive technologies in which   1. Hydrocarbon Removal Effi ciency: At
          Maximum Recommended                 hydrocarbons are removed through surface   an equivalent fl ow rate of 1.0gpm per
          Operating Conditions                adsorption onto the medium, TruBind   10-inch cartridge the TruBind cartridge
          Temperature:                        cartridges utilize a proprietary modifi ed   typically reduces trace hydrocarbon
            150°F (65°C) @ 20psid (1.4bar); 180°F  polymer that both absorbs and chemically   contaminant in excess of 95% in
            (82°C) @10psid (0.7bar)           binds the hydrocarbon molecules into   single pass mode. This effi ciency
          Pressure:                           its interior matrices. The affi nity of the   level can be maintained only to a net
            40psid (2.8bar) @ 75°F (24°C)     polymeric absorbent for hydrocarbon   differential pressure of 10psi. Series or
          Flow Rate:                          contaminant is so great that accelerated   multipass fi ltration can virtually eliminate
            1.0gpm per 10-inch cartridge      testing by the Toxic Characteristics   hydrocarbon contamination.
          Change-out Pressure Drop (net):     Leachate Procedure (TCLP) indicated the   2. Hydrocarbon Absorbent Capacity:
           10psi (0.7bar)                     effl uent hydrocarbon level in water to be   The TruBind cartridge medium has the
          Flow Factor:                        below current and proposed EPA limits.   potential to remove up to 250 grams
            0.03psid per 1gpm at 1cks viscosity per  The modifi ed polymer was formulated   (approximately one-half pint) of low
            10 in cartridge                   to control the speed of hydrocarbon   density hydrocarbon contaminant. On
          pH Range: 2 - 12                    absorption by eliminating the potential for   this basis, the table below provides
          Lengths: 10-40 in (249mm-1016mm)    skin formation at the polymer/hydrocarbon   expected life data in hours orgallons
                                              interface. Consequently this polymer, when
          Dimensions:                         incorporated into a radial-fl ow-design   at several trace contaminant levels
          Outside Diameter: 2½˝ in (63.5 mm)  cartridge, insures maximum utilization of   based on a 1.0gpm fl ow rate per 10-
                        1 ˝
          Inside Diameter: 1 ⁄ 16  in (27 mm)  surface area. The nature of the polymer   inch cartridge. Absorbent capacity will
                                                                                    decrease as density of hydrocarbon
                                              makes it an effective absorbent for free,
          Bio-safety:                                                               increases.
          The TruBind cartridge is classifi ed as non-  emulsifi ed and dissolved oils, synthetic   3. Flow Rate Capability: A maximum fl ow
          hazardous and incinerable. Disposal must   lubricants, grease and a multitude of   rate of 1.0gpm per 10-inch length
                                              organic solvents.
          be dictated by local regulations pertaining                               cartridge is recommended for the most
          to the absorbed contaminant.                                              effective removal of trace hydrocarbon
                                                                                    contaminant.
                                                                                   Estimated   Use the following equations
                                         Hydrocarbon
            Hydrocarbon   Concentration  removal per   Estimated life   Gallons fl uid   cost per   to calculate performance:
              (ppm)       % by weight                     in hours     treated     gallon of   Life (Hrs.) = 1100.8/PPM
                                         minute (grams)                                       Removal Rate (Grams/Min)
                                                                                  treated fl uid
                                                                                              = PPM/264.2
                10           .001            0.04          106.0        6,330        $.003
               100            .01            .40           10.6          633         $.03
               1,000          .1             4.00           1.1          63          $.30
           Note: Cost per gallon decreases signifi cantly with longer cartridges.

          Ordering Information
              TBC


           Cartridge Series    Length         Support Core    (QG &DS &RQ¿JXUDWLRQ      Seal Material
           TruBind Absorbent   FRGH     LQ     PP   A = Standard Wall  DO = Double-Open-End  A   3RO\ROH¿Q )RDP *DVNHW
           Cartridge            ǫÝ             Polypropylene Core       JDVNHW VHDO   (standard for “DO” seal design)
                         10    9 13 » 16Ý
                                 ǫÝ                           DX = DOE w/core extender  N = Buna-N O-Ring
                         20    19 15 » 16Ý                    TC = Single-Open-End  (standard for “TC” seal design)
                                 óÝ                              (222 O-ring seal)
                         30    30 » 16Ý                       7;       2 ULQJ )OH[ )LQ
                                1
                         39    39      991


          Specifi cations are subject to change without notifi cation.                           © 2010 Parker-Hannifi n Corporation
          For User Responsibility Statement, see www.parker.com/safety                    domnick hunter Process Filtration - North America
                                                                                                          All Rights Reserved
                                                                                     Fulfl o is a registered trademark of Parker-Hannifi n Corporation
                                                                                                      DS_IP_TruBind 300  Rev. A


                                                             89