          Fulfl o  TruBind  400 Filter Cartridge
          SPECIFICATIONS
          Materials of Construction:          Recommended Vessels:                Performance
            Absorbent: Proprietary polymer    Parker LTG10 and LTG20 polymeric    TruBind absorbent cartridge effi ciency de-
            Support Construction: 100% polyolefi n  vessels and equivalent competitive vessels.  pends upon the residence time of the
            Seal Material: Polyethylene Foam                                      fl uid within the cartridge, which is a function
                                                                                  of the volumetric fl ow rate.
          Cartridge Dimensions (nominal)      Technology                          1. Hydrocarbon Removal Effi ciency: At
            Lengths:                          Unlike competitive technologies in which   an equivalent fl ow rate of 3.0gpm per
               13
             9  ⁄ 16 in (249mm)               hydrocarbons are removed through surface   10-inch cartridge the TruBind cartridge
             19  ⁄ 16 in (506mm)              adsorption onto the medium, TruBind   typically reduces trace hydrocarbon
                15
            Outside Diameter:                 cartridges utilize a proprietary modifi ed   contaminant in excess of 95% in single
             4 ½ in (114 mm)                  polymer that both absorbs and chemically   pass mode. This effi ciency level can be
            Inside Diameter:                  binds the hydrocarbon molecules into its   maintained only to a net differential pres-
             1  ⁄ 16 in (27 mm)               interior matrices. The affi nity of the poly-  sure of 10psi. Series or multipass fi ltra-
               1
                                              meric absorbent for hydrocarbon contami-  tion can virtually eliminate hydrocarbon
          Maximum Recommended Operating       nant is so great that accelerated testing by   contamination.
          Conditions:                         the Toxic Characteristics Leachate Proce-  2. Hydrocarbon Absorbent Capacity:
            Temperature:                      dure (TCLP) indicated the effl uent hydrocar-  The TruBind cartridge medium has the
              150°F (65°C) @20psid (1.4bar);   bon level in water to be below current and   potential to remove up to 500 grams
              180°F (82°C) @10psid (0.7bar)   proposed EPA limits. The modifi ed polymer   (approximately one pint) of low density
            Pressure:                         was formulated to control the speed of   hydrocarbon contaminant. On this basis,
             40psid (2.8bar) @ 75°F (24°C)    hydrocarbon absorption by eliminating the   the table below provides expected life
            Flow Rate:                        potential for skin formation at the polymer/  data in hours orgallons at several trace
             3.0gpm per 10-inch cartridge     hydrocarbon interface. Consequently this   contaminant levels based on a 3.0gpm
            Change-out Pressure Drop (net):   polymer, when incorporated into a radial-  fl ow rate per 10-inch cartridge. Absor-
             10psi (0.7bar)                   fl ow-design cartridge, insures maximum   bent capacity will decrease as density of
            Flow Factor:                      utilization of surface area. The nature of the   hydrocarbon increases.
             0.1psid per 1gpm at 1cks viscosity   polymer makes it an effective absorbent for   3. Flow Rate Capability: A maximum
              per 10 in cartridge             free, emulsifi ed and dissolved oils, syn-  fl ow rate of 3.0gpm per 10-inch length
              pH Range: 2 - 12                thetic lubricants, grease and a multitude of   cartridge is recommended for the most
                                              organic solvents.
          Bio-safety:                                                               effective removal of trace hydrocarbon
          The TruBind cartridge is classifi ed                                       contaminant.
          as non-hazardous and incinerable.
          Disposal must be dictated by local                                      Use the following equations to calculate
          regulations pertaining to the absorbed                                  performance:
          contaminant.                                                            Life (Hrs.) = 800/PPM
                                                                                  Removal Rate (Grams/Min) = PPM/90

                                                                                   Estimated
                                         Hydrocarbon
           Hydrocarbon   Concentration   removal per   Estimated life   Gallons fl uid   cost per
              (ppm)       % by weight                    in hours      treated     gallon of
                                         minute (grams)
                                                                                  treated fl uid
                10           .001            0.11          80.0        14, 400       $.002
               100           .01             1.10           8.0         1,400        $.025
               1,000          .1            11.00           0.8         144          $.24
           Note: Cost per gallon decreases signifi cantly with longer cartridges.

          Ordering Information

                    TBC

                 Cartridge Code  Outside Diameter  Cartridge Length  Support Core  End Cap Configuration   Seal Material
                TruBind Cartridge  Code  in  mm  Code in   mm  A = Standard Wall  DO = Double-Open-End  A = Polyolefin Foam
                               4    4-1/2  114  10  9-13/16  249  Polypropylene Core   (gasket seal)   Gasket (standard for
                                              20   19-15/16  506                                    “DO” seal design)



          Specifi cations are subject to change without notifi cation.                           © 2010 Parker-Hannifi n Corporation
          For User Responsibility Statement, see www.parker.com/safety                    domnick hunter Process Filtration - North America
                                                                                                          All Rights Reserved
                                                                                     Fulfl o is a registered trademark of Parker-Hannifi n Corporation
                                                                                                      DS_IP_TruBind 400  Rev. A


                                                             91
   86   87   88   89   90   91   92   93   94   95   96