Page 475 - Wago_PCB_TerminalBlocksConnectors_Volume2_2015_US
P. 475
Accessories
Lockout Caps, Insulation Stops and Fixing Elements 6
MCS MIDI 473
Lockout caps Insulation stops Fixing elements
for male and female connectors for male and female connectors for angled male headers
equipped with CAGE CLAMP ® equipped with CAGE CLAMP or with solder pins
®
®
CAGE CLAMP S
Pack.
Color Item No. Pack. Unit Color Conductor Size Item No. Color Item No. Pack. Unit
Unit
Lockout cap Insulation stop, Fixing element
5/5.08 mm pin spacing
gray 231-668 500 (5 x 100) white 0.08–0.2 mm “sol.” 231-670 200 gray 231-193 100
2
0.08–0.14 mm “f-st”
2
orange 231-669 500 (5 x 100) orange 231-393 100
light gray 0.25–0.5 mm 231-671 200
2
dark gray 0.75–1 mm 2 231-672 200 6
Insulation stop, Screws for fixing elements
7.5/7.62 mm pin spacing
Screw with nut
white 0.08–0.2 mm “sol.” 231-673 200 M 2 x 12 231-195 100
2
0.08–0.14 mm “f-st”
2
Tapping screw
light gray 0.25–0.5 mm 231-674 200 B 2.2 x 13 231-194 100
2
dark gray 0.75–1 mm 2 231-675 200 Drilled hole, 1.8 mm Ø
®
Sealing unnecessary clamping points in CAGE CLAMP - Wiring of PLC and microprocessor control systems also Fixing elements enhance connection reliability between
equipped male and female connectors (e.g., when employs small or very small fine-stranded conductors. The male headers with angled solder pins and the PCB. This
doubling the pin spacing to meet clearance and creepage buckling strength of these conductors is so low that they substantially reduces mechanical stress on both solder pins
distance requirements, or when higher rated voltage is can bend in the clamp when they come into contact with and joints, particularly when dealing with small lengths
required). Lockout pins are not suitable for panel-mount, the stop, meaning the insulation can penetrate into the and frequent mating cycles.
angled female connectors. clamping unit be clamped with the conductor.
This is possible with all of the clamping systems currently
on the market and results in time-consuming troubleshoot-
ing.
Insulation stop for connectors reliably ensure proper
termination.
Insulation stops automatically bundle the cores of fine-
stranded conductors when inserted into the clamping unit,
preventing splaying. This also limits the conductor entry
to a defined cross sectional area — ensuring the actual
conductor, not the insulation, will enter the clamping unit.
Insulation stops are available as dividable 5-pole strips for
MCS MIDI male and female connectors.
Insulation stop usage will not affect the conductor strip
lengths for the aforementioned connectors.
Insulation stops are not suitable for panel-mounted female
10.16 mm pin spacing available upon request. connectors.