HY28-2665-01/P1/EN Medium Duty Axial Piston Pumps
Dimensional Data P1/PD Series
Pump Installation - P1/PD 100
End Ports
139.9
“L” Control Option to Load Sense Port "X" D3 Case Drain Port
123.2 Max. Volume Stop
49.1 (CCW Rotation)
Min. Volume Stop
(CW Rotation)
BG Gage Optional
Outlet Port
44.6
159.9 Max. Volume Stop
D1 Case Drain Port 191.9 (CW Rotation)
Min. Volume Stop
282.6 (CCW Rotation)
Optional
340.8 Maximum
Pressure
Compensator
Adjusting Screw D2 Case Drain Port
Load Sense 143.7
Adjusting Screw 120.5 102.0 3.9 173.2
CW Control 99.0 Plug
Location
CW Rotation
Arrow
"X" Load Sense
Port
120 114.4
113
51.0
53.5
122
115
117.1
CCW Arrow 115.5
Location
CCW Control 16.9
15.3
Location Nameplate
For Shaft & Flange
Dimensions, see page 58
2X 45.7
(to Drain Ports)
42.5 56.0
2X 71˚ P1/PD 100 Port Sizes
SAE ISO BSP
2X 102.0 31.8
A Inlet 63mm 63mm —
(to Drain Ports)
30.3 code 61 C DN 64 B
63.5 44.45 W Threads ½ - 13 M12 x 1.75 B —
62.0 33.35 UNC-2B C
66.7
B Outlet 32mm 32mm —
88.9
code 62 C DN 32 B
"B" Outlet Port
"A" Inlet Port Y Threads ½ - 13 M12 x 1.75 B —
UNC-2B C
Y (4 places)
W (4 places) BG SAE-4 D M12x1.5 A ¼" E
17.1 40.1 31.8 D1 D2 D3 SAE-12 D M27x2 A ¾" E
50.8
X SAE-4 D M12x1.5 A ¼" E
Note A: Metric o-ring boss port conform to ISO 6149-1
Note B: Metric 4-bolt flange port conforms to ISO 6162
Note C: Inch 4-bolt flange port conforms to SAE J518
Note D: Inch o-ring boss port conforms to SAE J514
Note E: BSP boss port conforms to ISO 228-1
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio USA 59