Page 135 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 135

Gefran Spa - Drive & Motion Control Unit • www.gefran.com             135

          9.  Programming


          9.1	 “GF_eXpress”		PC	Configuration	Tool
          Applications                                        The creation of custom parameter menus with a limited sub-set
          •   Parameter configuration of Gefran devices (Instruments, Drives,   of data is envisaged, to enable better and more effective device   ADV200 - 4
             Sensors)                                         configuration.
          •   Tuning of control parameters with on-line tests and trends
          •   Management of parameter archive for multiple configuration  GF_eXpress  is  based  on  HTML  technology.  The  graphic  layout
                                                              and content are intuitive and easy to use.
          Features                                            The interface and descriptions of the configuration parameters are
          •   Guided product selection                        available in multi-language format.                   ADV200-DC
          •   Simplified settings                             The use and support of UNICODE format, for multi-language man-
          •   Multiple languages
          •   Parameter printout                              agement, enables the inclusion of languages that use special char-
          •   Creation and storing of recipes                 acters (Chinese, Korean, Russian, etc.).
          •   Network autoscan
                                                              GF_eXpress also offers the following functions:


                                                              •  Autoscan                                           ADV200 - 6
                                                              Device connection parameters can be configured manually or us-
                                                              ing the Autoscan function.
                                                              The Autoscan function automatically searches for the device con-
                                                              nected to the development PC, sending serial commands to iden-
                                                              tify the type and parameters of communication.        ADV100
          GF_eXpress is the software used to configure the parameters of
          the  automation  components,  drives  and  sensors  in  the  Gefran   •   Monitor Window
          catalogue.                                          When the device is connected, the configuration pages display the
                                                              value of the single parameter in real-time.
          The  procedures  for  selecting  and  configuring  parameters  are
          easy and intuitive, thanks to the graphic interface and devices are   Besides displaying the value the Monitor Window also enables pa-  ADV80
          grouped according to product type and functions.    rameters to be modified in real-time.
          Product searches are performed by means of a context search and
          a visual selection from among actual images of the products.  •  Recipes
                                                              Saving and archiving a list of parameters. This function is used to
          This makes it possible to have a single library of devices for all   manage same configurations on different devices or the transfer of
          Gefran products.                                    configurations between different users.               AFE200
          All details for configuration of each single device are set out in XML
          format to facilitate expansion of the catalogue and parameters.  •  Oscilloscope
                                                              Simultaneous monitoring of up to 8 curves. The reference value
                                                              for the curve being displayed can be selected from among all the
                                                              variables that are available for the selected device.  FFE200

                                                              •  Print
                                                              Prints the variables that are displayed or selected. The Print func-
                                                              tion also includes the preview.

                                                              •  Technical data
                                                              Operating systems:                                    SMB200
                                                              •   Windows ® 2000, XP, Vista, 7.
                                                              Minimum PC requirements:
                                                              •   Pentium class CPU
                                                              •   512 MB of RAM
                                                              •   Free space of > 200MB
                                                              •   Graphic card min. VGA (1024x768)
                                                              •   1 RS232 or USB serial port
                                                              •   1 Ethernet port (for other Gefran devices, e.g. Geflex)  PROGRAM.
                                                              •   CD-ROM drive
                                                              Communication protocols supported:
                                                              •   Serial communication with the device (Modbus)
                                                              •   Ethernet communication with TCP Modbus devices
          The selected product can be configured as follows:  •
                                                                                                                    APPENDIX
          •   using a sub-set of predefined parameters
          •   using a guided graphic interface with context menus