Page 136 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 136
136 Inverter System & Power Supply Unit
9.2 Programming Keypad
ADV200 - AFE200 - FFE200 ADV80
The KB_ADV programming keypad (supplied as standard) makes The integrated programming keypad allows fast programming and
the man-machine interface simple, immediate and highly functional. immediate start-up.
PROGRAMMAZIONE • Keypad, GF_eXpress, MDPlc, ...
ADV200 - 4 • Basic
The programming software is available in 2 modes, Easy and Ex- • 1-line x 4-character alphanumerical LED dis-
pert, suitable for users of any level and all programming require- play with sign
ments, however complex. • Drive START and STOP keys
• Simple parameter modification
The powerful platform also features a menu/parameter structure • Menu displayed in text format, individual pa-
that is easy to interpret and is facilitated by the keypad functions rameters in numerical format
and display. • Fast navigation keys
• Alarm codes displayed
The “Wizard” tool ensures totally user-friendly immediate start- • Resetting of alarms from keypad.
up functions. Standard features of the ADV200/AFE/FFE include
programming in 10 languages (English, Italian, French, German, Prg Rev Fwd Limit Alarm
Spanish, Polish, Romanian, Russian, Turkish and Portuguese). S.000
AI Op
Parameter code (Mains voltage)
• 4 line x 21 character display Menu S (STARTUP)
• Alphanumeric plaintext ADV100
• Complete information regarding each parameter
• Fast navigation keys The optional K-ADV100 programming keypad featuring full display
• Key for displaying the last 10 parameters that of parameters and variables in 10 languages makes the ADV100
have been changed extremely intuitive and easy to use.
• DISP key for rapid display of operating pa-
rameters It has a strip of magnetic material on the back so that it can be at-
• Uploading-Downloading and saving of 5 tached to the front of the drive or other metal surface (e.g. door of
complete sets of drive parameters the electrical panel).
• Remote control from a distance of up to 10
metres. • 5 line x 21 character display
• Alphanumeric plaintext
• Complete information regarding each parameter
• Fast navigation keys
• Key for displaying the last 10 parameters that
have been changed
• DISP key for rapid display of operating pa-
rameters
• Uploading-Downloading and saving of 5
complete sets of drive parameters
• Remote control from a distance of up to 15
metres (a 70 cm-long connection cable is
supplied as standard).
9.3 Softscope
SoftScope is a software oscilloscope with synchronous sampling
(buffered with a minimum sampling time of 1ms). Using SoftScope
the user can easily display in a fast way some specific variables,
for example commissioning variables, variables to test perform- Speed cycle
Start, ramp reference 1500 rpm,
ance levels achieved or to tune the control loops. ramp output reaches 1500 rpm, Stop,
ramp reference 0 rpm, ramp output
SoftScope allows the definition of the following parameters: reaches 0 rpm.
• Trigger conditions (e.g. climbing leading edge of a specific signal) 1) start command
• Recording quality (a multiple of the basic clock at 1ms) 2) ramp input speed reference
3) ramp output
• Recording duration period
• System sizes to be recorded.
The curves can be displayed with different colours and they can
be enabled/disabled. The zoom function allows enlargement of the
details. The cursor allows detection of the signal peaks and dura-
tion.
The recorded data are displayed as time-based curves and there-
fore can be analysed. The displayed curves can be printed and Zoom
stored in ASCII format and can be used with the most common Ramp output phase from 0 rpm to
1500 rpm of the previous cycle.
data processing tools (for example Excel, Matlab).
1) start command
2) ramp input speed reference
3) ramp output