Example Part Number :  ISF       1     T     B    N      I    X     Z     0     P  150  PS       G    R1  BR

        YOUR PART NUMBER :              1     T                 I    X

                Section  ——>   1        2     3     4     5    6     7     8     9  10  11  12  13              14




         1  Series                                                 9  Zero Offset Pressure

          ISF    Intrinsically Safe F-Series (potted for natural gas)   This is an example. Your number will be the bottom
                                                                   14.7   of your desired pressure range. Most often your
        ISQB    Intrinsically Safe QB-Series                            number will be ‘0’.



         2  Type                                                  10  Full Scale Pressure Type
           1    Single Loop                                          N    100% Pressure Ends Below Atmosphere

                                                                      P    100% Pressure Ends Above Atmosphere (Typical)
         3  Sensor Type                                               Z    100% Pressure Ends at Zero

           T    -14.7 to 150 psig
                                                                  11  Full Scale Pressure

         4  Manifold Material                                      150   This is an example. Your number will be the top of

           B    Brass (Standard)                                        your desired pressure range.
           A    Aluminum
                                                                  12  Pressure Unit

         5  Thread Type                                             PS    PSI                        Inches Hg    IH
                                                                    MB    Millibars                Inches H2O    IW
           N    NPT (Standard)
                                                                    BR    Bar                        Mm H2O    MW
           P    BSPP
                                                                    KP    Kilopascal            Kilograms cm²    KG
                                                                    MP    Megapascal                      Torr    TR
         6  Input Signal Range
                                                                   MH    mm Hg
            I    4 to 20 mADC

                                                                  13  Pressure Unit of Measure
         7  Monitor Signal Range                                     A    Absolute Pressure

           X    No Monitor Signal                                    G    Gage Pressure



         8  Zero Offset                                           14  Popular Options

           N    0% Pressure Starts Below Atmosphere                 R1    Rotate Connector 180 Degrees
           P    0% Pressure Starts Above Atmosphere                 BR    Install Foot Bracket
           Z    0% Pressure Starts at Zero (Typical)               Please call if you need assistance with your application








                                                      OIL & GAS *  PROPORTION-AIR.COM  *  LET’S TALK:  317.335.2602  |  877.331.1738    7