Page 66 - Parker - Pressure Control Valves
P. 66
Catalog HY15-3502/US Dual Cross-Over Relief Valve
Technical Information Series XRDH101
CV
Dimensions Millimeters (Inches)
78.4 (3.09) 63.5 Check Valves
Max. (2.50)
6.4 50.8 SH
(.25) (2.00)
A
Shuttle Valves
Ø 7.1 (.28) 6.4 (.25) LM
Thru Mounting Hollow Hex.
Hole (2) Places
127.0 Load/Motor
(5.00) Controls
44.5
(1.75) 106.3 FC
RVA (4.19)
20.7 Controls
RVB Flow
(.82)
41.1
(1.62) PC
B
15.9 Pressure Controls
220.5 (8.68) (.63)
Max. 31.8
THIRD-ANGLE LE
PROJECTION
(1.25)
Ordering Information Logic Elements
RVA RVB
DC
Directional Controls
XRDH101
10 Size Adjustment Pressure Optional Adjustment Pressure Optional Seals Port
Dual Cross-Over Style Range Pressure Style Range Pressure Size MV
Relief Valve Setting Setting
Code Adjustment Style / Kit No. Optional Pressure Setting Code Port Size Part No. Manual Valves
F Fixed style, preset at factory. Pressure ÷ 10 Omit Cartridge Only
K Knob Adjust (717784-10) i.e. 235 = 2350 PSI 8T SAE-8 830318 SV
(Requires 2) (Omit if standard setting is used) Steel body only.
Setting Range:
S Screw Adjust 100 to 5000 PSI Individual body requires 2 SAE 6 plugs.
Part number 6 HP50N-S.
T Tamper Resistant Cap (717943) All settings at 11.3 LPM (3 GPM) Solenoid Valves
(Requires 2)
PV
Code Seals
Code Pressure Range
Omit “D”-Ring
10 6.9 - 69 Bar (100 - 1000 PSI) Proportional
Standard Setting: N Nitrile Valves
34.5 Bar (500 PSI) @ 11.3 LPM (3 GPM) V Fluorocarbon
20 34.5 - 138 Bar (500 - 2000 PSI) CE
Standard Setting:
69 Bar (1000 PSI) @ 11.3 LPM (3 GPM)
30 69 - 207 Bar (1000 - 3000 PSI) Coils & Electronics
Standard Setting: Note: A 6.9 Bar (100 PSI) pressure differential must be maintained
103.5 Bar (1500 PSI) @ 11.3 LPM (3 GPM) between the two relief valve settings. If both reliefs are adjustable and
have the same pressure range; it is not necessary to repeat the BC
50 138 - 345 Bar (2000 - 5000 PSI) adjustment and setting.
Standard Setting: i.e. XRDH101S50-8T means that both A & B reliefs are screw adjustable
172.4 Bar (2500 PSI) @ 11.3 LPM (3 GPM) and have a range of 138 - 345 Bar (2000 - 5000 PSI). Bodies & Cavities
TD
Technical Data
PC64 Parker Hannifin Corporation