Page 82 - Parker - Pressure Control Valves
P. 82
Catalog HY15-3502/US P.O. Sequence Valve (Internal Pilot)
Technical Information Series SVH161
CV
Dimensions Millimeters (Inches)
Check Valves
SH
38.1 (1.50)
Dia. Knob
36.4 36.9 39.5 38.8 Shuttle Valves
(1.43) (1.45) (1.55) (1.53)
LM
Load/Motor
1-1/2" Hex. Controls
1-5/16-12 UN-2A 99 Nm
Thread (73 lb. ft.)
(3) Torque FC
72.1
(2.84)
Flow Controls
(2)
PC
Pressure Controls
(1) Ø 26.9 (1.06)
Ø 28.5 (1.12)
LE
Screw/Knob Version Fixed Cap/Tamper Resistant Version
THIRD-ANGLE
PROJECTION Elements
Logic
DC
Directional Controls
Ordering Information
SVH161
MV
16 Size Adjustment Pressure Seals Optional Body Port
P.O. Sequence Style Range Pressure Material Size
Valve Setting Manual Valves
(Internal Pilot)
SV
Code Adjustment Style / Kit No. Code Seals / Kit No. Code Body Material
F Fixed style, preset at factory. Omit Nitrile / (SK16-3) Omit Steel
K Knob Adjust (717784-15) V Fluorocarbon / (SK16-3V) A Aluminum Solenoid Valves
S Screw Adjust
T Tamper Resistant Cap (717785) Optional Pressure Setting Code Port Size Body Part No. PV
Pressure ÷ 10 Omit Cartridge Only
Code Pressure Range i.e. 235 = 2350 PSI 12T SAE-12 (B16-3-*12T) Proportional
(Omit if standard setting is used) Valves
10 6.9 - 69 Bar (100 - 1000 PSI) Setting Range: 16T SAE-16 (B16-3-*16T)
Standard Setting: 100 to 5000 PSI * Add “A” for aluminum, omit for steel.
34.5 Bar (500 PSI) All settings at 11.3 LPM (3 GPM) CE
@ 11.3 LPM (3 GPM)
20 13.8 - 138 Bar (200 - 2000 PSI) Electronics
Standard Setting: Coils &
69 Bar (1000 PSI)
@ 11.3 LPM (3 GPM) BC
30 20.7 - 207 Bar (300 - 3000 PSI)
Standard Setting:
103.5 Bar (1500 PSI) Bodies & Cavities
@ 11.3 LPM (3 GPM)
50 34.5 - 345 Bar (500 - 5000 PSI)
Standard Setting: TD
172.4 Bar (2500 PSI)
Technical Data
@ 11.3 LPM (3 GPM)
PC80 Parker Hannifin Corporation
Hydraulic Cartridge Systems