Page 92 - Parker - Pressure Control Valves
P. 92
Catalog HY15-3502/US P.O. Sequence Valve, Kick-Down
Technical Information Series B04C3
CV
Dimensions Millimeters (Inches)
Check Valves
5 AF Hex socket
SH
21.8
(0.86)
max Shuttle Valves
17 AF Hex.
12 Nm LM
(9 lb. ft.)
Torque
39.5 26 AF Hex. Load/Motor Controls
(1.56) 50 Nm
(37 lb. ft.)
Torque FC
Flow Controls
7/8" - 14 UNF
PC
(3)
47.5
(1.87) Pressure Controls
(2) LE
Logic
(1) Elements
DC
Directional
Ordering Information Controls
B04C3 MV
10 Size Pressure Adjustment Optional Seals
Kick-Down Adjustment Style Pressure Manual Valves
Pilot Operated Range Setting
Sequence Valve
SV
Code Pressure Adjustment Range Optional Pressure Setting Order Bodies Separately
H 10 - 210 Bar (145 - 3000 PSI) Specify setting if required (Bar) Solenoid Valves
P 10 - 420 Bar (145 - 6000 PSI) B04C3H Standard Setting: LB10
100 Bar (1450 PSI) Line Body Porting Body PV
B04C3P Standard Setting: Material
Code Adjustment Style / Kit No. 200 Bar (2900 PSI)
Z Screw Adjust (Std.) Code Porting Proportional Valves
W Knob Adjust 710 5/8″ SAE (main)
Code Seals / Kit No.
T Tamper Resistant Cap (TC1130) 3/8″ SAE (aux) CE
N Nitrile, Buna-N (Std.) /
(SK30504N-1) 711 3/4″ BSP (main)
1/4″ BSP (aux)
V Fluorocarbon / Coils & Electronics
(SK30504V-1)
Code Body Material
A Aluminum BC
S Steel
Bodies & Cavities
TD
Technical Data
PC90 Parker Hannifin Corporation
Hydraulic Cartridge Systems