Page 10 - Parker - Vane pumps single, double, triple T6 mobile application
P. 10
ORDERING CODE - T6CM SERIES MOBILE APPLICATION
Model No. T6CM - B22 - 1 R 00 - C 1
Series M = Mobile 1 shaft seal Modification
Cam ring Seal class
(Delivery at 0 PSI & 1200 r.p.m.) 1 = S1 (for mineral oil)
B03 = 3.42 GPM B17 = 18.48 GPM 4 = S4 (for the resistant fluids)
B05 = 5.45 GPM B20 = 20.23 GPM 5 = S5 (for mineral oil and fire
B06 = 6.76 GPM B22 = 22.28 GPM resistant fluids)
B08 = 8.36 GPM B25 = 25.14 GPM
B10 = 10.81 GPM B28 = 27.90 GPM Design letter
B12 = 11.76 GPM B31 = 31.70 GPM Porting combination
B14 = 14.58 GPM 00 = standard
Type of shaft Direct. of rotation (view on shaft end)
1 = keyed (SAE B) R = clockwise
2 = keyed (no SAE) L = counter-clockwise
3 = splined (SAE B)
4 = splined (SAE BB)
P = Pressure port
S = Suction port
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)
T6CM - B22
Internal leakage Qs [GPM] Lp. Noise level [db(A)] 1m ISO 4412
Pressure p [PSI] Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or
viscosity if internal leakage is more than 50% of theoretical flow.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
Power loss Ps [HP] Load F [Lbs]
Pressure p [PSI] Speed n [RPM]
Maximum permissible axial load Fa = 180 Lbs
Parker Hannifin
10 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France