Page 12 - Parker - Vane pumps single, double, triple T6 mobile application
P. 12

ORDERING CODE - T6CP SERIES MOBILE APPLICATION

            Model No.                          T6CP -  B22  -  2 R 00 - A 1

            Series P = Mobile 2 shaft seals                                     Modification
            Cam ring                                                            Seal class
            (Delivery at 0 PSI & 1200 r.p.m.)                                   1 = S1 (for mineral oil)
            B14 = 14.58 GPM  B25 = 25.14 GPM                                    4 = S4 (for the resistant fluids)
            B17 = 18.48 GPM  B28 = 27.90 GPM                                    5 = S5 (for mineral oil and fire
            B20 = 20.23 GPM  B31 = 31.70 GPM                                                 resistant fluids)
            B22 = 22.28 GPM
                                                                                Design letter
            Type of shaft
            2 = keyed (no SAE)                                                  Porting combination
            3 = splined (SAE C)                                                 00 = standard
                                                                                Direct. of rotation (view on shaft end)
                                                                                R = clockwise
                                                                                L = counter-clockwise


                                                                                P = Pressure port
                                                                                S = Suction port


                       INTERNAL LEAKAGE (TYPICAL)                         NOISE LEVEL (TYPICAL)
                                                                                  T6CP - B22



              Internal leakage Qs [GPM]                        Lp. Noise level [db(A)] 1m ISO 4412














                              Pressure p [PSI]                                 Pressure p [PSI]
            Do not operate the pump more than 5 seconds at any speed or
            viscosity if internal leakage is more than 50% of theoretical flow.





                POWER LOSS HYDROMECHANICAL (TYPICAL)                    PERMISSIBLE RADIAL LOAD







              Power loss Ps [HP]                               Load F [Lbs]












                              Pressure p [PSI]                                  Speed n [RPM]

                                                                Maximum permissible axial load Fa = 180 Lbs





                                                                                         Parker Hannifin
                         12                        Back To The Table Of Content          Denison Vane Pump Division
                                                                                         Vierzon - France
   7   8   9   10   11   12   13   14   15   16   17