Page 28 - Parker - Vane pumps single, double, triple T6 mobile application
P. 28

TECHNICAL DATA - T6DCCM SERIES MOBILE APPLICATION

                      INTERNAL LEAKAGE (TYPICAL)                          NOISE LEVEL (TYPICAL)
                                                                          T6DCCM - B38 - B22 - B22










              Internal leakage Qs [GPM]                        Lp. Noise level [db(A)] 1m ISO 4412


















                              Pressure p [PSI]                                 Pressure p [PSI]
            Total leakage is the sum of each section loss at its operating  Triple pump noise level is given with each section discharging
            conditions.                                         at the pressure noted on the curve.





                POWER LOSS HYDROMECHANICAL (TYPICAL)                    PERMISSIBLE RADIAL LOAD














              Power loss Ps [HP]                               Load F [Lbs]



















                              Pressure p [PSI]                                 Speed n [RPM]

            Total hydrodynamic power loss is the sum of each section at its  Maximum permissible axial load Fa = 180 Lbs
            operating conditions.





                         28                         Back To The Table Of Content         Parker Hannifin
                                                                                         Denison Vane Pump Division
                                                                                         Vierzon - France