Page 29 - Parker - Vane pumps single, double, triple T6 mobile application
P. 29

TECHNICAL DATA - T6EDC* SERIES MOBILE APPLICATION

                      INTERNAL LEAKAGE (TYPICAL)                          NOISE LEVEL (TYPICAL)
                                                                          T6EDCM - 062 - B35 - B17










              Internal leakage Qs [l/min]                      Lp. Noise level [db(A)] 1m ISO 4412



















                              Pressure p [bar]                                 Pressure p [bar]
            Total leakage is the sum of each section loss at its operating  Triple pump noise level is given with each section
            conditions.                                         discharging at the pressure noted on the curve.





                POWER LOSS HYDROMECHANICAL (TYPICAL)                    PERMISSIBLE RADIAL LOAD














              Power loss Ps [HP]                               Load F [Lbs]




















                              Pressure p [PSI]                                 Speed n [RPM]
            Total hydrodynamic power loss is the sum of each section at its  Maximum permissible axial load Fa = 449 Lbs
            operating conditions.




                                                                                         Parker Hannifin
                         29                         Back To The Table Of Content         Denison Vane Pump Division
                                                                                         Vierzon - France
   24   25   26   27   28   29   30   31   32   33   34